A 250-GHz microwave interferometer for divertor experiments on DIII-D
Authors:
- 1 January 1995
- journal article
- conference paper
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 66 (1) , 422-424
Abstract
A new 250‐GHz, two‐frequency microwave interferometer system has been developed to diagnose divertor plasmas on DIII‐D. This diagnostic will measure the line‐averaged density across both the inner and outer, lower divertor legs. With a cutoff density of over 7×1014 cm−3, temporal measurements of edge localized modes (ELMs) and plasma detachment are expected. The outer‐leg system will use a double‐pass method while the inner‐leg system will be single pass. Two special three‐dimensional (3D) carbon composite tiles are used, one to protect the microwave antennas mounted directly under the strike point and the other as the outer‐leg reflecting surface. Performance, design constraints, and the thermal‐mechanical design of the 3D carbon composite tiles are discussed.Keywords
This publication has 1 reference indexed in Scilit:
- The effect of ELMs on edge plasma scaling in DIII-DJournal of Nuclear Materials, 1992