Motion Artifact Reduction in Wearable Photoplethysmography Based on Multi-Channel Sensors with Multiple Wavelengths
Top Cited Papers
Open Access
Abstract
Photoplethysmography (PPG) is an easy and convenient method by which to measure heart rate (HR). However, PPG signals that optically measure volumetric changes in blood are not robust to motion artifacts. In this paper, we develop a PPG measuring system based on multi-channel sensors with multiple wavelengths and propose a motion artifact reduction algorithm using independent component analysis (ICA). We also propose a truncated singular value decomposition for 12-channel PPG signals, which contain direction and depth information measured using the developed multi-channel PPG measurement system. The performance of the proposed method is evaluated against the R-peaks of an electrocardiogram in terms of sensitivity (Se), positive predictive value (PPV), and failed detection rate (FDR). The experimental results show that Se, PPV, and FDR were 99%, 99.55%, and 0.45% for walking, 96.28%, 99.24%, and 0.77% for fast walking, and 82.49%, 99.83%, and 0.17% for running, respectively. The evaluation shows that the proposed method is effective in reducing errors in HR estimation from PPG signals with motion artifacts in intensive motion situations such as fast walking and running.Keywords
Funding Information
- National Research Foundation of Korea (2018R1A5A7025522)
This publication has 25 references indexed in Scilit:
- Improving Pulse Rate Measurements during Random Motion Using a Wearable Multichannel Reflectance PhotoplethysmographSensors, 2016
- Multiparameter Respiratory Rate Estimation From the PhotoplethysmogramIEEE Transactions on Biomedical Engineering, 2013
- PCA and ICA processing methods for removal of artifacts and noise in electrocardiograms: A survey and comparisonApplied Soft Computing, 2011
- The non-invasive and continuous estimation of cardiac output using a photoplethysmogram and electrocardiogram during incremental exercisePhysiological Measurement, 2010
- Motion-tolerant magnetic earring sensor and wireless earpiece for wearable photoplethysmographyIEEE Transactions on Information Technology in Biomedicine, 2010
- Noninvasive cardiac output estimation using a novel photoplethysmogram index2009
- Simultaneous recording of skin blood pulsations at different vascular depths by multiwavelength photoplethysmographyApplied Optics, 2007
- Motion Artifact Reduction in Photoplethysmography Using Independent Component AnalysisIEEE Transactions on Biomedical Engineering, 2006
- Validation du Sport Tester PE 3000 en fonction de l'enregistrement HolterScience & Sports, 1987
- Photophysical processes in recent medical laser developments: A reviewLasers in Medical Science, 1986