Aging assessment method of oil–paper composite insulation based on repeated polarization current characteristics
Open Access
- 12 October 2021
- journal article
- research article
- Published by Institution of Engineering and Technology (IET) in IET Science, Measurement & Technology
- Vol. 16 (1) , 59-68
Abstract
To explore the aging assessment method of the oil–paper insulation in power transformers, the polarization and depolarization current (PDC) characteristics of oil–paper composite insulation samples are investigated under high applied voltage. Based on the asymmetry of polarization absorption current and depolarization current and the polarity effect of insulation pressboard, the repeated polarization current test method is proposed. A novel aging characteristic parameter, which is the ratio of the normalized charge for the first polarization and the normalized charge for the second polarization, is extracted. The difference between the decay rates of the first polarization current and the second polarization current increases at first and then decreases with the polarization time, and decreases with increasing aging degree of the pressboard. The more serious the insulation aging is, the smaller the variation range of aging characteristic parameter with polarization time is, and the closer the value is to 1. With decrease in the DP, the maximum of aging characteristic parameter changes in a decreasing trend. The aging condition of the oil–paper composite insulation can be assessed by the repeated polarization current method and the relationship between the aging characteristic parameter and the polarization time.Keywords
This publication has 29 references indexed in Scilit:
- Fault classification in power transformer using polarization depolarization current analysis2015
- Dielectric spectroscopic measurements on transformer oil-paper insulation under controlled laboratory conditionsIEEE Transactions on Dielectrics and Electrical Insulation, 2008
- Optimal Time Selection for the Polarisation and Depolarisation Current Measurement for Power Transformer Insulation Diagnosis2007 IEEE Power Engineering Society General Meeting, 2007
- Investigation of an Expert System for the Condition Assessment of Transformer Insulation Based on Dielectric Response MeasurementsIEEE Transactions on Power Delivery, 2004
- Investigation of polarization and depolarization current measurements for the assessment of oil-paper insulation of aged transformersIEEE Transactions on Dielectrics and Electrical Insulation, 2004
- Aging of Oil-Impregnated Paper in Power TransformersIEEE Transactions on Power Delivery, 2004
- Degradation of cellulosic insulationin power transformers.Part 4: Effects of ageing on the tensile strength of paperIEE Proceedings - Science, Measurement and Technology, 2000
- Kerr electro-optic field measurement and charge dynamics in transformer-oil/solid composite insulation systemsIEEE Transactions on Dielectrics and Electrical Insulation, 1997
- Electrical field distribution in transformer oilIEEE Transactions on Electrical Insulation, 1992
- A review of paper aging in power transformersIEE Proceedings C Generation, Transmission and Distribution, 1985