Peripheral tissue oximetry: comparing three commercial near-infrared spectroscopy oximeters on the forearm
Open Access
- 30 August 2013
- journal article
- research article
- Published by Springer Nature in Journal of Clinical Monitoring and Computing
- Vol. 28 (2) , 149-155
Abstract
Estimation of regional tissue oxygenation (rStO2) by near infrared spectroscopy enables non-invasive end-organ oxygen balance monitoring and could be a valuable tool in intensive care. However, the diverse absolute values and dynamics of different devices, and overall poor repeatability of measurements are a problem. The aim of the present study is to test the hypothesis that INVOS 5100C, FORE-SIGHT and NONIN EQUANOX 7600 have similar properties concerning absolute values, repeatability, and sensitivity to changes in rStO2. To test repeatability the sensors were repositioned 20 times during hemodynamic steady state on the adult forearm. Afterwards six vascular occlusions by inflation of an upper arm cuff were done to achieve low oxygenation in the forearm. Absolute values were compared by repeated-measures ANOVA, repeatability was estimated by the within-subject standard deviation, Sw, and response to changing oxygenation by the down slope of rStO2 during vascular occlusion in the respective arm. 10 healthy adults, 21–29 years old, with double skinfolds on the forearm less than 10 mm participated. The median rStO2 was 70.7 % (interquartile range (IQR) 7.7 %), 68.4 % (IQR 8.4 %), and 64.6 % (IQR 4.8) with INVOS, NONIN, and FORE-SIGHT, respectively, the median rate of decline was 13.2 %/min (IQR 9.6), 22.8 %/min (IQR 18.0), and 10.8 %/min (IQR 6.0), and the same-site repeatability was 2.9 % (95 % CI 2.4–3.3), 4.6 % (CI 3.9–5.3), and 2.0 % (CI 1.7–2.3). INVOS gave significantly higher steady state values than FORE-SIGHT, and NONIN had the steepest decline in rStO2, but the poorest repeatability. Two measures of signal-to-noise were similar among devices. This suggests that good repeatability comes at the expense of low sensitivity to changes in oxygenation. Values of rStO2 on the forearm from INVOS, NONIN and FORE-SIGTH cannot be used interchangeably.Keywords
This publication has 18 references indexed in Scilit:
- Monitoring tissue oxygenation by near infrared spectroscopy (NIRS): background and current applicationsJournal of Clinical Monitoring and Computing, 2012
- Tissue oximetry: a comparison of mean values of regional tissue saturation, reproducibility and dynamic range of four NIRS-instruments on the human forearmBiomedical Optics Express, 2011
- Regional tissue oxygen saturation: comparability and reproducibility of different devicesJournal of Biomedical Optics, 2011
- Assessment of tissue oxygen saturation during a vascular occlusion test using near-infrared spectroscopy: the role of probe spacing and measurement site studied in healthy volunteersCritical Care, 2009
- Low tissue oxygen saturation at the end of early goal-directed therapy is associated with worse outcome in critically ill patientsCritical Care, 2009
- Is thenar tissue hemoglobin oxygen saturation in septic shock related to macrohemodynamic variables and outcome?Critical Care, 2009
- Changes in Anesthesia & Analgesia for 2009Anesthesia & Analgesia, 2009
- Precision of measurement of cerebral tissue oxygenation index using near-infrared spectroscopy in preterm neonatesJournal of Biomedical Optics, 2006
- Reproducibility of cerebral oxygenation measurement in neonates and infants in the clinical setting using the NIRO 300 oximeter*Pediatric Critical Care Medicine, 2005
- In Vivo Near-Infrared SpectroscopyAnnual Review of Biomedical Engineering, 2000