Abstract
Surface waves could provide a more reliable and efficient alternative to conventional ultrasonic rail inspection for the detection of surface cracks. In this work, suitable guided wave modes have been efficiently excited by using a phased array probe in conjunction with a spatial averaging method to enhance the signal‐to‐noise‐ratio. A study of the scattering behavior from different gauge corner defect geometries has shown that deep defects can be detected even with multiple smaller ones in front.