Abstract
Background: The QRS axis of the electrocardiogram (ECG) is often considered in clinical practice, but its determination is frequently limited to a rough estimation, such as “normal”, with left or right deviation, and superior or inferior in the case of premature ventricular complexes (PVCs). However, a more exact determination of the QRS axis may be warranted in certain scenarios, such as to determine the origin of PVCs more precisely, and is attainable by visual estimation using the hexaxial reference system. Objectives: The aim of this study was to determine how well such an estimation of the QRS axis would correlate with the axis calculated by formulas. Materials and methods: A PVC database from 2012–2020 was used to extract 12-lead ECGs of patients with outflow tract PVCs and analyze the QRS axes of regularly conducted beats as well as PVCs. QRS axes were determined visually by two physicians with the help of the hexaxial reference system to an accuracy of 10° on the one hand, and were calculated using three previously described formulas based on QRS voltages on the other. Results: A total of 216 QRS complexes from 108 patients were analyzed (108 regularly conducted beats and 108 PVCs). Estimated QRS axes of regularly conducted beats and PVCs were 39 ± 40° and 88 ± 15°, respectively. Calculated QRS axes of regularly conducted beats according to the three formulas were 37 ± 40°, 36 ± 40° and 35 ± 38°, respectively. Calculated QRS axes of PVCs according to the three formulas were 87 ± 15°, 87 ± 14° and 86 ± 16°, respectively. Correlation coefficients showed strong correlations between the estimated and the three calculated values for regularly conducted beats (0.98, 0.97 and 0.98) and PVCs (0.94, 0.94 and 0.94). Conclusions: A sophisticated visual estimation of the QRS axis correlates well with voltage-based calculations and can therefore be considered sufficient for most purposes.Keywords
Funding Information
- Medizinische Hochschule Hannover (MHH)
This publication has 25 references indexed in Scilit:
- Ventricular tachycardia site of origin prediction by a QRS axis-based algorithm confirmed by heterogenous tissue channel localization obtained from artificial-intelligence-powered CMR analysisEP Europace, 2023
- A subtype electrocardiogram pattern on idiopathic ventricular arrhythmias originating around the pulmonary right sinus: discordance between electrocardiographic classification and three-dimensional mappingEP Europace, 2023
- Prognostic Value of Cardiac Axis Deviation in Systemic Sclerosis–Related Pulmonary HypertensionArthritis Care & Research, 2022
- Electrocardiographic characteristics and ablation of ventricular arrhythmias originating from the basal inferoseptal areaEP Europace, 2021
- Lokalisation ventrikulärer Extrasystolen im 12-Kanal-EKGHerzschrittmachertherapie + Elektrophysiologie, 2021
- Left axis deviation in patients with left bundle branch block is a marker of myocardial disease associated with poor response to cardiac resynchronization therapyJournal of Electrocardiology, 2020
- Ventricular arrhythmias with superior axis originating from the left ventricular septum: electrocardiographic characteristics predicting successful ablation and insights into their mechanism-observations from a small series of patientsEP Europace, 2015
- QRS‐T Angle: A ReviewAnnals of Noninvasive Electrocardiology, 2014
- Prognostic Electrocardiographic Parameters in Patients with Suspected MyocarditisEuropean Journal of Heart Failure, 2011
- QRS Axis Validation in Clinical ElectrocardiographyThe American Journal of Cardiology, 2008