EMI Noise Reduction for the Single-Phase Grid-Connected Inverter With A Modified Harmonic Filter Design
- 8 December 2020
- journal article
- research article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 63 (3) , 739-751
Abstract
Harmonics and conducted electromagnetic interference (EMI) are two main issues in grid-connected inverter system. In this article, a modified LCL-LC harmonic filter is structured to strengthen its EMI suppression ability. Considering the common mode and differential mode EMI propagation paths, the traditional LCL-LC filter is split into a symmetrical topology, and with the midpoint of the split filtering capacitors connected to the midpoint of the dc-link capacitor. Compared to the traditional LCL-LC filter, the modified one can maintain the satisfied harmonic attenuation ability and strengthen the EMI suppression. Also, a double closed-loop control strategy is employed to solve the severe resonance problem caused by the harmonic filter. Moreover, a system calibration method is proposed and introduced to design the controller parameters to improve the high-order grid-connected system's stability. A comprehensive analysis and discussions concerning the traditional and modified LCL-LC filters are conducted in simulation and experiment on a 2 kW/220 V/50 Hz single-phase grid-connected inverter. The results have verified the feasibility of the proposed design method, and shown the superiority of the modified LCL-LC filter and active damping strategy in EMI mitigation. Besides, the weight and volume of the harmonic filter can be significantly reduced through this strategy.Keywords
Funding Information
- National Natural Science Foundation of China (52007122)
- Foundation of Shenzhen Science and Technology Committee (JCYJ20200109105204077)
This publication has 28 references indexed in Scilit:
- Grid-Current-Feedback Control for LCL-Filtered Grid Converters With Enhanced StabilityIEEE Transactions on Power Electronics, 2016
- An Efficient and Robust Hybrid Damper for $LCL$- or $LLCL$-Based Grid-Tied Inverter With Strong Grid-Side Harmonic Voltage Effect RejectionIEEE Transactions on Industrial Electronics, 2015
- Active Damping of LLCL-Filter Resonance Based on LC-Trap Voltage or Current FeedbackIEEE Transactions on Power Electronics, 2015
- Common-mode EMI noise reduction for grid-interface converter in low-voltage DC distribution system2012
- Mitigation of Dynamic, Unbalanced, and Harmonic Voltage Disturbances Using Grid-Connected Inverters With $LCL$ FilterIEEE Transactions on Industrial Electronics, 2010
- Filter-Based Active Damping of Voltage Source Converters With $LCL$ FilterIEEE Transactions on Industrial Electronics, 2010
- An Active EMI Filtering Technique for Improving Passive Filter Low-Frequency PerformanceIEEE Transactions on Electromagnetic Compatibility, 2006
- Grid current regulation of a three-phase voltage source inverter with an LCL input filterIEEE Transactions on Power Electronics, 2003
- Multilevel inverters: a survey of topologies, controls, and applicationsIEEE Transactions on Industrial Electronics, 2002
- Input Filter Design2001