CAD/CAM fabrication accuracy of long‐ vs. short‐span implant‐supported FDPs
- 3 November 2014
- journal article
- research article
- Published by Wiley in Clinical Oral Implants Research
- Vol. 26 (3) , 245-249
Abstract
Objective: To compare the precision of fit of long‐span vs. short‐span implant‐supported screw‐retained fixed dental prostheses (FDPs) made from computer‐aided‐design/computer‐aided‐manufactured (CAD/CAM) titanium and veneered with ceramic. The null hypothesis was that there is no difference in the vertical microgap between long‐span and short‐span FDPs.Materials and methods: CAD/CAM titanium frameworks for an implant‐supported maxillary FDP on implants with a flat platform were fabricated on one single master cast. Group A consisted of six 10‐unit FDPs connected to six implants (FDI positions 15, 13, 11, 21, 23, 25) and group B of six 5‐unit FDPs (three implants, FDI positions 21, 23, 25). The CAD/CAM system from Biodenta Swiss AG (Berneck, Switzerland) was used for digitizing (laser scanner) the master cast and anatomical CAD of each framework separately. The frameworks were milled (CAM) from a titanium grade V monobloc and veneered with porcelain. Median vertical distance between implant and FDP platforms from the non‐tightened implants (one‐screw test on implant 25) was calculated from mesial, buccal, and distal scanning electron microscope measurements.Results: All measurements showed values P = 0.002; 97.5% CI −27.3 to −4.9) and insignificant at implant 23 (P = 0.093; −3.9 to 1.0).Conclusions: CAD/CAM fabrication including laboratory scanning and porcelain firing was highly precise and reproducible for all long‐ and short‐span FDPs. While all FDPs showed clinically acceptable values, the short‐span FDPs were statistically more precise at the 5‐unit span distance.Keywords
This publication has 18 references indexed in Scilit:
- In Vitro Measurements of Precision of Fit of Implant‐Supported Frameworks. A Comparison between “Virtual” and “Physical” Assessments of Fit Using Two Different Techniques of MeasurementsClinical Implant Dentistry and Related Research, 2011
- A Comparison of Fit of CNC‐Milled Titanium and Zirconia Frameworks to ImplantsClinical Implant Dentistry and Related Research, 2011
- Precision of Fit to Implants: A Comparison of Cresco™ and Procera® Implant Bridge FrameworksClinical Implant Dentistry and Related Research, 2010
- Beam transfer characteristics of a commercial environmental SEM and a low vacuum SEMJournal of Microscopy, 2010
- Marginal and internal fits of fixed dental prostheses zirconia retainersDental Materials, 2009
- Digital dentistry: an overview of recent developments for CAD/CAM generated restorationsBritish Dental Journal, 2008
- Biologic Response of Immediately versus Delayed Loaded Implants Supporting Ill-Fitting Prostheses: An Animal StudyClinical Implant Dentistry and Related Research, 2005
- Finite element analysis on dental implant–supported prostheses without passive fitJournal of Prosthodontics, 2002
- Fit of three porcelain-fused-to-metal marginal designs in vivo: A scanning electron microscope studyThe Journal of Prosthetic Dentistry, 1985
- The estimation of cement film thickness by an in vivo techniqueBritish Dental Journal, 1971