Performance of a Novel Dual-Electrode Bipolar Radiofrequency Ablation Device a Chronic Porcine Study
Authors:
- 1 January 2011
- journal article
- research article
- Published by SAGE Publications in Innovations: Technology and Techniques in Cardiothoracic and Vascular Surgery
- Vol. 6 (1) , 17-22
Abstract
Objective: Over recent years, a variety of energy sources, including bipolar radiofrequency, have been used to replace the traditional incisions of the Cox-Maze procedure for the surgical treatment of atrial fibrillation (AF). The purpose of this study was to evaluate the safety and efficacy of a novel dual-electrode bipolar radiofrequency ablation device Synergy (Atricure, Inc., Cincinnati, OH USA) for AF in a chronic porcine model. Methods: Six domestic pigs underwent a modified Cox-Maze IV procedure without cardiopulmonary bypass using the Synergy device. Animals survived for 30 days. Each pig then underwent induction of AF and was killed to remove the heart en bloc for histologic assessment. Each ablation line was dissected perpendicularly at 5-mm intervals to assess the lesion width, depth, and transmurality. Results: All animals survived the operation. Electrical isolation of the left atrial appendage and the pulmonary veins were documented by pacing acutely and at 30 days after the operation in all six animals. All animals failed to be induced in AF at 30 days. There was no gross evidence of intra-atrial thrombus formation or stricture of the pulmonary veins. All ablations (n = 209) examined were discrete, linear, and transmural, with a mean lesion width of 3.0 ± 0.7 mm and a mean lesion depth of 5.4 ± 3.3 mm. The mean ablation time was 16.3 ± 4.4 seconds, with a mean total energy delivery of 238 ± 170 J. Conclusions: The Atricure Synergy was able to create reliable chronic transmural lesions of the modified Cox-Maze IV procedure on a porcine beating heart without cardiopulmonary bypass. The ablation lines were significantly wider when compared with its predecessor, the Isolator II.Keywords
This publication has 28 references indexed in Scilit:
- Efficacy and safety of right and left atrial ablations on the beating heart with irrigated bipolar radiofrequency energy: A long-term animal studyThe Journal of Thoracic and Cardiovascular Surgery, 2006
- Alternative Energy Sources for the Ablation of ArrhythmiasPacing and Clinical Electrophysiology, 2005
- A Prospective Multicenter Trial of Bipolar Radiofrequency Ablation for Atrial Fibrillation: Early ResultsThe Annals of Thoracic Surgery, 2004
- Successful Performance of Cox-Maze Procedure on Beating Heart Using Bipolar Radiofrequency Ablation: A Feasibility Study in AnimalsThe Annals of Thoracic Surgery, 2004
- A prospective, single-center clinical trial of a modified Cox maze procedure with bipolar radiofrequency ablationThe Journal of Thoracic and Cardiovascular Surgery, 2004
- Alternative Energy Sources for Surgical Atrial AblationJournal of Cardiac Surgery, 2004
- Atrial fibrillation ablation during mitral valve surgery using the Atricure™ deviceOperative Techniques in Thoracic and Cardiovascular Surgery, 2004
- The Cox maze III procedure for atrial fibrillation: long-term efficacy in patients undergoing lone versus concomitant proceduresThe Journal of Thoracic and Cardiovascular Surgery, 2003
- Cox-Maze Procedure for Atrial Fibrillation: Mayo Clinic ExperienceSeminars in Thoracic and Cardiovascular Surgery, 2000
- Modification of the maze procedure for atrial flutter and atrial fibrillationThe Journal of Thoracic and Cardiovascular Surgery, 1995