Motion Sickness in Mixed-Reality Situational Awareness System
Open Access
- 7 March 2024
- journal article
- research article
- Published by MDPI AG in Applied Sciences
- Vol. 14 (6) , 2231
Abstract
This research focuses on enhancing the user experience within a Mixed-Reality Situational Awareness System (MRSAS). The study employed the Simulator Sickness Questionnaire (SSQ) in order to gauge and quantify the user experience and to compare the effects of changes to the system. As the results of SSQ are very dependant on inherent motion sickness susceptibility, the Motion Sickness Susceptibility Questionnaire (MSQ) was used to normalize the results. The experimental conditions were tested on a simulated setup which was also compared to its real-life counterpart. This simulated setup was adjusted to best match the conditions found in the real system by using post-processing effects. The test subjects in this research primarily consisted of 17–28 years old university students representing both male and female genders as well as a secondary set with a larger age range but predominantly male. In total, there were 41 unique test subjects in this study. The parameters that were analyzed in this study were the Field of View (FoV) of the headset, the effects of peripheral and general blurring, camera distortions, camera white balance and users adaptability to VR over time. All of the results are presented as the average of multiple user results and as scaled by user MSQ. The findings suggest that SSQ scores increase rapidly in the first 10–20 min of testing and level off at around 40–50 min. Repeated exposure to VR reduces MS buildup, and a FoV of 49–54 is ideal for a MRSAS setup. Additionally camera based effects like lens distortion and automatic white balance had negligible effests on MS. In this study a new MSQ based SSQ normalization technique was also developed and utilized for comparison. While the experiments in this research were primarily conducted with the goal of improving the physical Vegvisir system, the results themselves may be applicable for a broader array of VR/MR awareness systems and can help improve the UX of future applications.Keywords
Funding Information
- Vegvisir (Defensphere OÜ)
This publication has 33 references indexed in Scilit:
- Effects of prolonged use of virtual reality smartphone-based head-mounted display on visual parameters: a randomised controlled trialScientific Reports, 2021
- Effect of latency on simulator sickness in smartphone virtual realityJournal of the Society for Information Display, 2021
- Effects of dynamic field-of-view restriction on cybersickness and presence in HMD-based virtual realityVirtual Reality, 2020
- A novel method for VR sickness reduction based on dynamic field of view processingVirtual Reality, 2020
- Virtual Reality Sickness: A Review of Causes and MeasurementsInternational Journal of Human–Computer Interaction, 2020
- Use of virtual reality simulators for training programs in the areas of security and defense: a systematic reviewMultimedia Tools and Applications, 2019
- Application and Prospect of Mixed Reality Technology in Medical FieldCurrent Medical Science, 2019
- Instability of the Perceived World While Watching 3D Stereoscopic Imagery: A likely Source of Motion Sickness SymptomsI-Perception, 2014
- Intra-visual conflict in visually induced motion sicknessDisplays, 2011
- The effect of internal and external fields of view on visually induced motion sicknessApplied Ergonomics, 2010