Improvements in multislice parallel imaging using radial CAIPIRINHA
Open Access
- 1 February 2011
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 65 (6) , 1630-1637
Abstract
Multislice parallel imaging involves the simultaneous sampling of multiple parallel slices which are subsequently separated using parallel imaging reconstruction. The CAIPIRINHA technique improves this reconstruction by manipulating the phase of the RF excitation pulses to shift the aliasing pattern such that there is less aliasing energy to be reconstructed. In this work, it is shown that combining the phase manipulation used in CAIPIRINHA with a non‐Cartesian (radial) sampling scheme further decreases the aliasing energy for the parallel imaging algorithm to reconstruct, thereby further increasing the degree to which a multi‐channel receiver array can be utilized for parallel imaging acceleration. In radial CAIPIRINHA, individual bands (slices) in a multislice excitation are modulated with view‐dependent phase, causing a destructive interference of entire slices. This destructive interference leads to a reduction in aliasing compared to the coherent shifts one observes when using this same technique with a Cartesian trajectory. Recovery of each individual slice is possible because the applied phase pattern is known, and a conjugate‐gradient reconstruction algorithm minimizes the contributions from other slices. Results are presented with a standard 12‐channel head coil with acceleration factors up to 14, where radial CAIPIRINHA produces an improved reconstruction when compared with Cartesian CAIPIRINHA. Magn Reson Med, 2011.Keywords
Funding Information
- Ohio Third Frontier Project Innovation Incentive Fellowship, Siemens Healthcare
- National Institutes of Health (R01-EB-004637, R01-HL-094557)
This publication has 20 references indexed in Scilit:
- Non‐Cartesian data reconstruction using GRAPPA operator gridding (GROG)Magnetic Resonance in Medicine, 2007
- 2D‐GRAPPA‐operator for faster 3D parallel MRIMagnetic Resonance in Medicine, 2006
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- Advances in sensitivity encoding with arbitrary k‐space trajectoriesMagnetic Resonance in Medicine, 2001
- SENSE: Sensitivity encoding for fast MRIMagnetic Resonance in Medicine, 1999
- Multishot rosette trajectories for spectrally selective MR imagingIEEE Transactions on Medical Imaging, 1997
- Wavelet encoding for 3D gradient‐echo MR imagingMagnetic Resonance in Medicine, 1996
- Frequency resolved single‐shot MR imaging using stochastic k‐space trajectoriesMagnetic Resonance in Medicine, 1996
- Phase‐offset multiplanar (POMP) volume imaging: A new techniqueJournal of Magnetic Resonance Imaging, 1991
- SIMAJournal of Computer Assisted Tomography, 1988