Assessment of Objective and Subjective Eccentric Refraction
Authors:
- 1 April 2005
- journal article
- research article
- Published by Wiley in Optometry and Vision Science
- Vol. 82 (4) , 298-306
Abstract
Purpose.: When performing perimetry, refracting subjects with central visual field loss, and in emmetropization studies, it is important to accurately measure peripheral refractive errors. Traditional methods for foveal refraction often give uncertain results in eccentric angles as a result of the large aberrations and the reduced retinal function. The aim of this study is therefore to compare and evaluate four methods for eccentric refraction. Methods.: Four eccentric methods were tested on 50 healthy subjects: one novel subjective procedure, optimizing the detection contrast sensitivity with different trial lenses, and three objective ones: photorefraction with a PowerRefractor, wavefront measurements with a Hartmann‐Shack sensor, and retinoscopy. The peripheral refractive error in the horizontal nasal visual field of the right eye was measured in 20° and 30°. Results.: In general, the eccentric refraction methods compared reasonably well. However, the following differences were noted. Retinoscopy showed a significant difference from the other methods in the axis of astigmatism. In 30° eccentric angle, it was not possible to measure 15 of the subjects with the PowerRefractor and the instrument also tended to underestimate high myopia (<‐6 D). The Hartmann‐Shack sensor showed a myopic shift of approximately 0.5 D in both eccentricities. The subjective method had a relatively larger spread. Conclusions.: This study indicates that it is possible to assess the eccentric refraction with all methods. However, the Hartmann‐Shack technique was found to be the most useful method. The agreement between the objective methods and the subjective eccentric refraction shows that detection contrast sensitivity in the periphery is affected by relatively small amounts of defocus.Keywords
Funding Information
- Carl Tryggers Stiftelse för Vetenskaplig Forskning
- Berit och Carl-Johan Wettergrens stiftelse
This publication has 36 references indexed in Scilit:
- Effects of Optically Imposed Astigmatism on Emmetropization in Infant MonkeysInvestigative Ophthalmology & Visual Science, 2004
- The effect of off-the-visual-axis retinoscopy on objective refractive measurementAmerican Journal of Ophthalmology, 2004
- Evaluation of the measurement of refractive error by the PowerRefractor: a remote, continuous and binocular measurement system of oculomotor functionBritish Journal of Ophthalmology, 2003
- Eccentric Correction for Off-Axis Vision in Central Visual Field LossOptometry and Vision Science, 2003
- Peripheral refractive errors in myopic, emmetropic, and hyperopic young subjectsJournal of the Optical Society of America A, 2002
- Monochromatic aberrations of human eyes in the horizontal visual fieldJournal of the Optical Society of America A, 2002
- Peripheral astigmatism in emmetropic eyesOphthalmic and Physiological Optics, 2001
- The first successful eccentric correctionVisual Impairment Research, 2001
- Laboratory, Clinical, and Kindergarten Test of a New Eccentric Infrared Photorefractor (PowerRefractor)Optometry and Vision Science, 2000
- REFRACTION FOR THE PERIPHERAL FIELD OF VISIONArchives of Ophthalmology (1950), 1931