Groundwater Flow in Sloping Aquifer under Localized Transient Recharge: Analytical Study
- 1 November 2013
- journal article
- Published by American Society of Civil Engineers (ASCE) in Journal of Hydraulic Engineering
- Vol. 139 (11) , 1165-1174
Abstract
This paper analyzes the groundwater flow system in an unconfined downward-sloping aquifer of semi-infinite extent in response to localized transient recharge. The aquifer is in contact with a water body of constant water level at one end and receives localized transient recharge from a recharge basin of finite width. The mathematical model is based on the Boussinesq equation with Dupuit-Forchheimer assumption, in which the spatial coordinate of the recharge basin is treated as an additional parameter. Analytical solutions of the linearized Boussinesq equation are obtained using the Laplace transform technique by dividing the aquifer in a three-zone system containing both Dirichlet and Neumann boundary conditions at the hypothetical interfaces. Upward- and zero-sloping cases are deduced from the main results by appropriately adjusting the slope parameter. To assess the validity and efficiency of the linearization method, the nonlinear Boussinesq equation is also solved using a fully explicit predictor-corrector numerical scheme. A numerical example is used for illustrating the effects of various parameters such as aquifer’s bed slope, spatial coordinate of the recharge basin, and recharge rate on the dynamic profiles of phreatic surface.Keywords
This publication has 40 references indexed in Scilit:
- WATER TABLE FLUCTUATIONS IN A SLOPING AQUIFER: ANALYTICAL EXPRESSIONS FOR WATER EXCHANGE BETWEEN STREAM AND GROUND-WATER WITH SURFACE INFILTRATIONJournal of Porous Media, 2010
- Analytical solution for groundwater flow in an anisotropic sloping aquifer with arbitrarily located multiwellsJournal of Hydrology, 2007
- Water table fluctuation owing to time-varying recharge, pumping and leakageJournal of Hydrology, 2006
- Response of a sloping aquifer to constant replenishment and to stream varying water levelJournal of Hydrology, 2001
- Aquifer response to stream-stage and recharge variations. I. Analytical step-response functionsJournal of Hydrology, 2000
- Modeling transient stream/aquifer interaction with the non-linear Boussinesq equation and its analytical solutionJournal of Hydrology, 1998
- Evaluation of the response of a water table to a variable recharge rateHydrological Sciences Journal, 1991
- Recharge to aquifers with mixed boundariesJournal of Hydrology, 1984
- Recharge from rectangular areas to finite aquifersJournal of Hydrology, 1981
- Water-table fluctuation in semipervious stream-unconfined aquifer systemsJournal of Hydrology, 1973