Optimized Processing of Fine-Needle Lymph Node Biopsies for Automated Immunostaining
Open Access
- 1 May 2010
- journal article
- research article
- Published by SAGE Publications in Journal of Veterinary Diagnostic Investigation
- Vol. 22 (3) , 383-388
Abstract
A straightforward, reliable technique for postcollection processing and evaluation of cytologic specimens for antigen detection using an automated immunostainer was developed. Visual assessment of cell suspension turbidity was used in parallel with light microscopic examination of concentrated cytospin preparations to verify the diagnostic utility of samples for immunocytochemical staining. Fine-needle lymph node biopsies from 81 dogs with lymphadenomegally and a cytologic or histologic diagnosis of lymphoma were introduced into ethylenediamine tetra-acetic acid tubes containing standardized storage media. Cell suspension turbidity was assessed to estimate cell concentration and resultant volume required for cytospin preparations with optimal cellularity. Preliminary cytospin preparations (using estimated volumes based upon turbidity) were stained using modified Wright stain and examined microscopically for intact neoplastic cell concentration. Once an optimal volume for cytospin preparations was established, additional concentrated slides were prepared for immunophenotyping, using an automated immunostainer and antibodies specific for cluster of differentiation (CD)79a and CD3e. All cell suspension samples with adequate gross turbidity had ample intact neoplastic cell concentration for immunocytochemical staining. Based on CD79a and CD3e expression, 51 (63%) B cell, 19 (23%) T cell, 3 mixed T and B cells (4%), and 3 non-T- and non-B-cell lymphomas (4%), as well as 5 (6%) nondiagnostic samples were identified. Three out of 5 of the nondiagnostic samples were submitted early in the investigation prior to the establishment of gross specimen turbidity guidelines. Immunocytochemical staining results were in complete agreement with all 6 available immunohistochemical correlates. The ability to visually assess sample adequacy prior to sample submission may encourage more widespread use of immunocytochemical techniques.Keywords
This publication has 21 references indexed in Scilit:
- Flow Cytometric Immunophenotype of Canine Lymph Node AspiratesJournal of Veterinary Internal Medicine, 2004
- Diagnosis of Canine Lymphoid Neoplasia Using Clonal Rearrangements of Antigen Receptor GenesVeterinary Pathology, 2003
- Canine T-cell Lymphomas: A Morphological, Immunological, and Clinical Study of 46 New CasesVeterinary Pathology, 2002
- Diagnosis and classification of lymphoma based on cytospin preparations: A comparison of hematopathologists and cytopathologistsDiagnostic Cytopathology, 2000
- Value and limitations of fine-needle aspiration cytology in diagnosis and classification of lymphomas: A reviewDiagnostic Cytopathology, 1999
- Immunophenotypic Comparison of Blood and Lymph Node from Dogs with LymphomaVeterinary Clinical Pathology, 1998
- Canine Lymphoma: Immunocytochemical Analysis of Fine-needle Aspiration BiopsyVeterinary Pathology, 1996
- Immunophenotyping Lymphomas in Dogs: A Comparison of Results From Fine Needle Aspirate and Needle Biopsy SamplesVeterinary Clinical Pathology, 1995
- Comparison of two methods of storing breast fine needle aspirates (FNAs) using oestrogen receptor immunocytochemical assay as a method of evaluating the storage methodsCytopathology, 1994
- Lymphomas in dogs a morphologic, immunologic, and clinical studyCancer, 1990