Early (6 months) results of a pilot prospective study to investigate the efficacy and safety of sirolimus coated balloon angioplasty for dysfunctional arterio-venous fistulas: MAgicTouch Intervention Leap for Dialysis Access (MATILDA) Trial
Open Access
- 27 October 2020
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (10) , e0241321
Abstract
The aim of this pilot study was to evaluate the safety and efficacy of the MagicTouch™ sirolimus-coated balloon (SCB) catheter (Concept Medical Inc., Tampa, FL, US) on improving the patency of failing arterio-venous fistulas (AVF) with de novo and recurrent stenoses. MATILDA reports early outcomes at 3- and 6 months post intervention. Single-centre, single-arm prospective pilot study of 33 (18 males; mean age 64.7±11.6 years) end-stage renal failure Asian patients with a dysfunctional AVF, who underwent SCB angioplasty between May 2019-January 2020. All procedures were performed under local anaesthetic without sedation and as day surgery. All patients were prescribed dual antiplatelet therapy for 3 months and followed up with Duplex ultrasound at 3 and 6 months. 47 stenotic target lesions treated and 24/33 (72.7%) patients were for restenosis. Main indications for intervention was low/dropping access flow (21/33; 63.6%) and most common target lesion was in the juxta-anastomosis (19/47; 40.4%). There was 100% technical and procedural success. There were no peri-procedural complications related to the SCB. The target lesion primary patency rates at 3 and 6 months were 46/47 (97.9%) and 29/35 (82.9%) respectively. Circuit access patency rates at 3 and 6 months were 31/33 (93.9%) and 17/25 (68%) respectively. There was one (2.9%) death at 6 months and 4/33 (12.1%) overall to date, all from patients’ underlying co-morbidities. SCB angioplasty for dysfunctional AVF circuits is a safe and efficacious modality in Asian haemodialysis patients at six months comparable if not better than the paclitaxel data reported to date in the literature.Keywords
This publication has 25 references indexed in Scilit:
- Is Repeat PTA of a Failing Hemodialysis Fistula Durable?International Journal of Vascular Medicine, 2014
- Emerging technologies: polymer-free phospholipid encapsulated sirolimus nanocarriers for the controlled release of drug from a stent-plus-balloon or a stand-alone balloon catheterEuroIntervention, 2013
- Associations between Hemodialysis Access Type and Clinical OutcomesJournal of the American Society of Nephrology, 2013
- Factors influencing technical success and outcome of percutaneous balloon angioplasty in de novo native hemodialysis arteriovenous fistulasEuropean Journal of Radiology, 2012
- Paclitaxel-Coated Balloon Angioplasty vs. Plain Balloon Dilation for the Treatment of Failing Dialysis Access:6-Month Interim Results From a Prospective Randomized Controlled TrialJournal of Endovascular Therapy, 2012
- Clinical Practice Guidelines for Vascular AccessAmerican Journal of Kidney Diseases, 2006
- Hemodialysis Vascular Access DysfunctionJournal of the American Society of Nephrology, 2006
- Sirolimus and Paclitaxel on Polymer-Based Drug-Eluting StentsJACC, 2006
- Reporting Standards for Percutaneous Interventions in Dialysis AccessJournal of Vascular and Interventional Radiology, 2003
- Vascular access use in Europe and the United States: Results from the DOPPSKidney International, 2002