Performance of procalcitonin in diagnosing parapneumonic pleural effusions
Authors:
Open Access
- 1 August 2017
- journal article
- research article
- Published by Wolters Kluwer Health in Medicine
- Vol. 96 (33) , e7829
Abstract
Parapneumonic pleural effusion (PPE) is a common complication of pneumonia. The accurate diagnosis of PPE remains a challenge. Recent studies suggest that procalcitonin (PCT) emerges as a potential biomarker for PPE. Our study aimed to determine the diagnostic value of PCT for PPE by a clinical study and summarize the overall diagnostic performance of PCT through a meta-analysis. Demographic and clinical data of the patients with PPE and controls were collected in our clinical study. The diagnostic performances of serum PCT (s-PCT) were analyzed via receiver operating characteristic (ROC) curve analysis, using area under the curve (AUC) as a measure of accuracy. Literature databases were systematically searched for the studies examining the accuracy of PCT for diagnosing PPE. Data on sensitivity, specificity, positive/negative likelihood ratio (PLR/NLR), and diagnostic odds ratio (DOR) were pooled. Summary ROC curves and AUC were used to evaluate overall test performance. In our clinical study, 47 patients with PPE and 101 controls were included. The s-PCT levels were significantly increased in the setting of PPE (5.44 ± 9.82 ng/mL) compared with malignant PE (0.15 ± 0.19 ng/mL), tuberculous PE (0.18 ± 0.16 ng/mL), and transudates (0.09 ± 0.03 ng/mL) (P < .001). Using a cutoff value of 0.195 ng/mL, the sensitivity and specificity of s-PCT in diagnosing PPE were 0.83 and 0.80, respectively, and AUC was 0.89. In addition, 11 studies were included in our meta-analysis. Summary performance estimates for s-PCT in diagnosing PPE were as follows: sensitivity, 0.78 (95% CI: 0.71–0.84); specificity, 0.74 (95% CI: 0.69–0.78); PLR, 3.46 (95% CI: 2.09–5.74); NLR, 0.27 (95% CI: 0.14–0.54); DOR, 12.37 (95% CI: 4.34–41.17); and AUC, 0.84. The corresponding estimates for p-PCT were as follows: sensitivity, 0.62 (95% CI: 0.57–0.67); specificity, 0.71 (95% CI: 0.68–0.75); PLR 2.31 (95% CI: 1.81–2.95); NLR, 0.47 (95% CI: 0.35–0.63); DOR, 5.48 (95% CI: 3.07–9.77); and AUC, 0.80. Both s-PCT and p-PCT might have modest performance in diagnosing PPE. However, more studies on a large scale should be performed to confirm our findings.Keywords
This publication has 30 references indexed in Scilit:
- Pleural effusion: diagnosis, treatment, and managementOpen Access Emergency Medicine, 2012
- Inflammatory biomarkers and prediction for intensive care unit admission in severe community-acquired pneumonia*Critical Care Medicine, 2011
- Diagnostic value of procalcitonin in pleural effusionsEuropean Journal of Clinical Microbiology & Infectious Diseases, 2010
- Infectious pleural effusions can be identified by sTREM-1 levelsRespiratory Medicine, 2010
- Biomarkers of infection for the differential diagnosis of pleural effusionsEuropean Respiratory Journal, 2009
- Serum and Pleural Fluid Procalcitonin in Predicting Bacterial Infection in Patients with Parapneumonic EffusionJournal of Korean Medical Science, 2009
- Parapneumonic Effusions and EmpyemaProceedings of the American Thoracic Society, 2006
- Bivariate analysis of sensitivity and specificity produces informative summary measures in diagnostic reviewsJournal of Clinical Epidemiology, 2005
- Quantifying heterogeneity in a meta‐analysisStatistics in Medicine, 2002
- High serum procalcitonin concentrations in patients with sepsis and infectionThe Lancet, 1993