Proximal Detection of Traces of Energetic Materials with an Eye-Safe UV Raman Prototype Developed for Civil Applications
Authors:
- Roberto ChiricoRCRoberto Chirico
- Salvatore AlmavivaSalvatore Almaviva
- Francesco ColaoFCFrancesco Colao
- Luca FioraniLuca Fiorani
- Marcello NuvoliMNMarcello Nuvoli
- Wenka SchweikertWSWenka Schweikert
- Frank SchnürerFSFrank Schnürer
- Luigi CassioliLCLuigi Cassioli
- Silvana GrossiSGSilvana Grossi
- Daniele MurraDMDaniele Murra
- Ivano MenicucciIMIvano Menicucci
- Federico AngeliniFederico Angelini
Open Access
Abstract
A new Raman-based apparatus for proximal detection of energetic materials on people, was developed and tested for the first time. All the optical and optoelectronics components of the apparatus, as well as their optical matching, were carefully chosen and designed to respect international eye-safety regulations. In this way, the apparatus is suitable for civil applications on people in public areas such as airports and metro or railway stations. The acquisition software performs the data analysis in real-time to provide a fast response to the operator. Moreover, it allows for deployment of the apparatus either as a stand alone device or as part of a more sophisticated warning system architecture made up of several sensors. Using polyamide as substrate, the apparatus was able to detect surface densities of ammonium nitrate (AN), 2-methyl-1,3,5-trinitrobenzene (TNT), 3-nitrooxy-2,2-bis(nitrooxymethyl)propyl] nitrate (PETN) and urea nitrate (UN) in the range of 100–1000 μg/cm2 at a distance of 6.4 m using each time a single laser pulse of 3 mJ/cm2. The limit of detection calculated for AN is 289 μg/cm2. AN and UN provided the highest percentages of true positives (>82% for surface densities of 100–400 μg/cm2 and fingerprints) followed by TNT and PETN (17%–70% for surface densities of 400–1000 μg/cm2 and fingerprints).Keywords
This publication has 27 references indexed in Scilit:
- Nanosecond Gated Raman Spectroscopy for Standoff Detection of Hazardous MaterialsBulletin of the Korean Chemical Society, 2014
- Raman Spectroscopy for Homeland Security ApplicationsInternational Journal of Spectroscopy, 2012
- Standoff detection of explosives: critical comparison for ensuing options on Raman spectroscopy–LIBS sensor fusionAnalytical and Bioanalytical Chemistry, 2011
- Deep Ultraviolet Resonance Raman Excitation Enables Explosives DetectionApplied Spectroscopy, 2010
- Near Real‐Time Standoff Detection of Explosives in a Realistic Outdoor Environment at 55 m DistancePropellants, Explosives, Pyrotechnics, 2009
- Laser-based standoff detection of explosives: a critical reviewAnalytical and Bioanalytical Chemistry, 2009
- Automated Detection of Fingerprint Traces of High Explosives Using Ultraviolet Raman SpectroscopyApplied Spectroscopy, 2009
- UV gated Raman spectroscopy for standoff detection of explosivesOptical Materials, 2008
- Stand-off Raman detection using dispersive and tunable filter based systemsSpectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 2005
- Standoff Detection of High Explosive Materials at 50 Meters in Ambient Light Conditions Using a Small Raman InstrumentApplied Spectroscopy, 2005