Design of cryogenic system for the Beijing Electron Positron Collider II upgrade
Open Access
- 1 January 2026
- journal article
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (01) , P01026
Abstract
The Beijing Electron Positron Collider II upgrade (BEPCII-U) has been proposed to optimize the maximum collision energy and data acquisition efficiency in higher energy region (>2.1 GeV). To achieve higher luminosity at higher energies, the number of superconducting radio frequency (SRF) cavities will be doubled. The cryogenic system of the BEPCII-U employs two cryogenic plants to provide the refrigeration for the three types of superconducting (SC) devices: SRF cavities, SC multi-function magnets (MFMs) and superconducting solenoid magnet (SSM). The cryogenic subsystem for SRF cavities has been upgraded from the original 500 W to 1 kW at 4.2 K due to the increased number of SRF cavities (4 cavities). The main tasks include the design of the cooling process, 499.8 MHz cavity cryomodules, local distribution valve boxes (LDVBs) and different types of multi-channel transfer lines (MCTLs) based on existing conditions. Meanwhile, the cryogenic subsystem for SC magnets has also been upgraded to enhance the reliability of the cryo-plant and to develop new SC MFM-cryomodules and associated valve boxes. The main tasks are including the design of the SC MFM-cryomodules, a cryogenic horizontal test stand (HTS) for SC magnets and working scheme for the main screw compressors (MSCs). The cryogenic system for the BEPCII-U has been designed, constructed and commissioned since the beginning of 2021, and the detailed design is presented in this paper.Keywords
This publication has 15 references indexed in Scilit:
- The design and testing of the gas-cooled high-temperature superconducting current leads for BEPCII-UpgradeNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2025
- Direct wind control software of the BEPCII Upgrade superconducting magnetRadiation Detection Technology and Methods, 2025
- Thermal performance analysis and cryogenic experimental measurements of the 166.6 MHz cavity cryomodule for the High Energy Photon SourceNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2024
- Development and tests of the 499.8 MHz srf cryomodules for HEPSJournal of Instrumentation, 2024
- The development of the 499.8 MHz superconducting cavity system for BEPCIINuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2021
- Overall Design of the ADS Injector I Cryogenic System in ChinaPhysics Procedia, 2015
- Design and system integration of the superconducting wiggler magnets for the Compact Linear Collider damping ringsPhysical Review Special Topics - Accelerators and Beams, 2012
- High power input coupler development for BEPCII 500MHz superconducting cavityNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2010
- Construction of Superconducting Magnet System for the J-PARC Neutrino Beam LineIEEE Transactions on Applied Superconductivity, 2010
- Interaction region design and realization for the Beijing Electron Positron ColliderNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2009