Abstract
In the present article, optimization of process variables has been done to maximize the removal efficiency of toxic HCl gas in a submerged self-priming venturi scrubber. Response surface methodology with central composite design has been chosen to predict the effect of process variables on the removal efficiency. A quadratic equation was found from this study to predict the removal efficiency and from the ANOVA test, the significance of process variables was evaluated. Regression analysis confirmed the suitability of the developed model by the higher R2 square value (0.9717). Optimum conditions were obtained as 55.18 m s–1 of throat gas velocity, 405.10 ppm of inlet HCl concentration and 0.0038 N of NaOH concentration in scrubbing liquid to achieve 90.80% of the HCl removal efficiency.
Funding Information
  • Chemical Engineering Department, Indian Institute of Technology Kharagpur, India
  • National Research Foundation of South Africa

This publication has 27 references indexed in Scilit: