Abstract
This paper presents an analysis of control trajectories for indirect and direct control of interior permanent magnet (IPM) synchronous motor drives. Since the inputs to the inner torque control loop of direct torque control (DTC) are the references for the torque and the amplitude of the stator flux linkage (lambdas), rather than id-iq plane in the indirect control, are transformed into the T-lambdas, plane. The experimental results show the excellent performance of the indirect and direct torque controller, incorporating control trajectories.

This publication has 11 references indexed in Scilit: