Analysis of bicarbonate, phosphate and other anions in saliva by capillary electrophoresis with capacitively coupled contactless conductivity detection in diagnostics of gastroesophageal reflux disease
- 3 November 2019
- journal article
- research article
- Published by Wiley in Electrophoresis
- Vol. 41 (1-2) , 116-122
Abstract
Bicarbonate and phosphate constitute major salivary buffering components, and their importance consists in the neutralization of acidic gastric contents during reflux episodes. In this work, capillary electrophoresis with capacitively coupled contactless conductivity detector was applied for the analysis of bicarbonate, phosphate, and another inorganic (chloride, nitrite, nitrate, sulfate, thiocyanate) and organic anions (acetate, butyrate) to evaluate their levels in saliva. The background electrolytes of different composition and pH between 6.02–9.41 were assessed for the bicarbonate and phosphate determination by comparison of the real analyses of a model solution with the simulation by PeakMaster software. The optimized background electrolyte was composed of 10 mM 2‐(N‐morpholino)ethanesulfonic acid, 20 mM arginine, and 30 µM cetyltrimethylammonium bromide, pH 8.95. Using this BGE, the anion levels were compared in saliva from 20 patients suffering from gastroesophageal reflux disease (GERD) and saliva from 12 healthy subjects. Bicarbonate levels were significantly elevated in saliva from GERD patients suggesting the possible applicability of bicarbonate as a biomarker in non‐invasive diagnostics of GERD by CE‐C4D.Keywords
Funding Information
- Ministerstvo Zdravotnictví Ceské Republiky (17–31945A)
- Ministerstvo Školství, Mládeže a Tělovýchovy
This publication has 36 references indexed in Scilit:
- Diagnostic Potential of Saliva: Current State and Future ApplicationsClinical Chemistry, 2011
- Rapid monitoring of arrays of amino acids in clinical samples using capillary electrophoresis with contactless conductivity detectionJournal of Separation Science, 2010
- Identification of inorganic ions in post‐blast explosive residues using portable CE instrumentation and capacitively coupled contactless conductivity detectionElectrophoresis, 2008
- Application of ion chromatography for the determination of inorganic ions, especially thiocyanates in human saliva samples as biomarkers of environmental tobacco smoke exposureJournal of Chromatography B, 2008
- Simultaneous determination of anions in nanoliter volumesKidney International, 2005
- Determination of major inorganic ions in blood serum and urine by capillary electrophoresis with contactless conductivity detectionAnalytica Chimica Acta, 2004
- Capacitively coupled contactless conductivity detection in capillary electrophoresisElectrophoresis, 2003
- Evaluation of diabetic ketoacidosis‐related ionic metabolites in human blood serum by capillary electrophoresisElectrophoresis, 2003
- Capillary Electrophoresis and Contactless Conductivity Detection of Ions in Narrow Inner Diameter CapillariesAnalytical Chemistry, 1999
- Surface‐charge reversed capillary zone electrophoresis of inorganic and organic anionsElectrophoresis, 1995