Preclinical Models of Restenosis and Their Application in the Evaluation of Drug-Eluting Stent Systems
Open Access
- 1 January 2010
- journal article
- review article
- Published by SAGE Publications in Veterinary Pathology
- Vol. 47 (1) , 58-76
Abstract
Coronary arterial disease (CAD) is the leading cause of death in the United States, the European Union, and Canada. Percutaneous coronary intervention (PCI) has revolutionized the treatment of CAD, and it is the advent of drug-eluting stent (DES) systems that has effectively allayed much of the challenge of restenosis that has plagued the success of PCI through its 30-year history. However, DES systems have not been a panacea: There yet remain the challenges associated with interventions involving bare metallic stents as well as newly arisen concerns related to the application of DES systems. To effectively address these novel and ongoing issues, animal models are relied on both to project the safety and efficacy of endovascular devices and to provide insight into the pathophysiology underlying the vascular response to injury and mechanisms of restenosis. In this review, preclinical models of restenosis are presented, and their application and limitation in the evaluation of device-based interventional technologies for the treatment of CAD are discussed.Keywords
This publication has 192 references indexed in Scilit:
- The Significance of Preclinical Evaluation of Sirolimus-, Paclitaxel-, and Zotarolimus-Eluting StentsThe American Journal of Cardiology, 2007
- The Pathophysiology and Burden of RestenosisThe American Journal of Cardiology, 2007
- Effects of Oral Prednisone After Stenting in a Rabbit Model of Established AtherosclerosisJACC, 2007
- Drug-eluting stents: results, promises and problemsInternational Journal of Cardiology, 2005
- Strain-Dependent Vascular Remodeling Phenotypes in Inbred MiceThe American Journal of Pathology, 2000
- A new expandable intracoronary tantalum (Strecker) stent: Early experimental results and follow-up to twelve monthsAmerican Heart Journal, 1993
- The coronary artery response to implantation of a balloon-expandable flexible stent in the aspirin- and non-aspirin-treated swine modelAmerican Heart Journal, 1991
- Atherosclerotic Yucatan microswine: An animalmodel with high-grade, fibrocalcific, nonfatty lesions suitable for testing catheter-based interventionsAmerican Heart Journal, 1990
- Intravascular Stents to Prevent Occlusion and Re-Stenosis after Transluminal AngioplastyNew England Journal of Medicine, 1987
- WHHL‐Rabbit: a low density lipoprotein receptor‐deficient animal model for familial hypercholesterolemiaFEBS Letters, 1980