Scaled, patient-specific 3D vertebral model reconstruction based on 2D lateral fluoroscopy
Authors:
- 20 July 2010
- journal article
- research article
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 6 (3) , 351-366
Abstract
Accurate three-dimensional (3D) models of lumbar vertebrae are required for image-based 3D kinematics analysis. MRI or CT datasets are frequently used to derive 3D models but have the disadvantages that they are expensive, time-consuming or involving ionizing radiation (e.g., CT acquisition). An alternative method using 2D lateral fluoroscopy was developed. A technique was developed to reconstruct a scaled 3D lumbar vertebral model from a single two-dimensional (2D) lateral fluoroscopic image and a statistical shape model of the lumbar vertebrae. Four cadaveric lumbar spine segments and two statistical shape models were used for testing. Reconstruction accuracy was determined by comparison of the surface models reconstructed from the single lateral fluoroscopic images to the ground truth data from 3D CT segmentation. For each case, two different surface-based registration techniques were used to recover the unknown scale factor, and the rigid transformation between the reconstructed surface model and the ground truth model before the differences between the two discrete surface models were computed. Successful reconstruction of scaled surface models was achieved for all test lumbar vertebrae based on single lateral fluoroscopic images. The mean reconstruction error was between 0.7 and 1.6 mm. A scaled, patient-specific surface model of the lumbar vertebra from a single lateral fluoroscopic image can be synthesized using the present approach. This new method for patient-specific 3D modeling has potential applications in spine kinematics analysis, surgical planning, and navigation.Keywords
This publication has 30 references indexed in Scilit:
- A 2D/3D correspondence building method for reconstruction of a patient-specific 3D bone surface model using point distribution models and calibrated X-ray imagesMedical Image Analysis, 2009
- Measurement of Vertebral Kinematics Using Noninvasive Image Matching Method–Validation and ApplicationSpine, 2008
- Investigation of in vivo 6DOF total knee arthoplasty kinematics using a dual orthogonal fluoroscopic systemJournal of Orthopaedic Research, 2006
- A Hierarchical Statistical Modeling Approach for the Unsupervised 3-D Biplanar Reconstruction of the Scoliotic SpineIEEE Transactions on Biomedical Engineering, 2005
- Fluoroscopy as an Imaging Means for Computer-Assisted Surgical NavigationComputer Aided Surgery, 1999
- Fluoroscopy as an imaging means for computer-assisted surgical navigationComputer Aided Surgery, 1999
- Use of active shape models for locating structures in medical imagesImage and Vision Computing, 1994
- A method for registration of 3-D shapesIEEE Transactions on Pattern Analysis and Machine Intelligence, 1992
- Eigenfaces for RecognitionJournal of Cognitive Neuroscience, 1991
- A Survey of the Statistical Theory of ShapeStatistical Science, 1989