Abstract
We present results from the first measurement of axial range components of fiducialized neutron induced nuclear recoil tracks using the DRIFT directional dark matter detector. Nuclear recoil events are fiducialized in the DRIFT experiment using temporal charge carrier separations between different species of anions in 30:10:1 Torr of CS2:CF4:O2 gas mixture. For this measurement, neutron-induced nuclear recoil tracks were generated by exposing the detector to 252Cf source from different directions. Using these events, the sensitivity of the detector to the expected axial directional signatures were investigated as the neutron source was moved from one detector axis to another. Results obtained from these measurements show clear sensitivity of the DRIFT detector to the axial directional signatures in this fiducialization gas mode.Keywords
All Related Versions
This publication has 52 references indexed in Scilit:
- First measurement of nuclear recoil head-tail sense in a fiducialised WIMP dark matter detectorJournal of Instrumentation, 2016
- Planck2015 resultsAstronomy & Astrophysics, 2016
- Dark Matter Candidates from Particle Physics and Methods of DetectionAnnual Review of Astronomy and Astrophysics, 2010
- Strong Lensing by GalaxiesAnnual Review of Astronomy and Astrophysics, 2010
- Particle Dark Matter2010
- Dark matter candidatesNew Journal of Physics, 2009
- Big Bang nucleosynthesis and particle dark matterNew Journal of Physics, 2009
- Republication of: The redshift of extragalactic nebulaeGeneral Relativity and Gravitation, 2008
- A Direct Empirical Proof of the Existence of Dark MatterThe Astrophysical Journal, 2006
- Particle dark matter: evidence, candidates and constraintsPhysics Reports, 2005