Retinal nerve fiber layer thickness after laser-assisted subepithelial keratomileusis and femtosecond LASIK: a prospective observational cohort study
Open Access
- 1 July 2018
- journal article
- research article
- Published by Taylor & Francis in Clinical Ophthalmology
- Vol. ume 12, 1213-1218
Abstract
Purpose: Based on the assumption that high levels of intraocular pressure (IOP) during femtosecond laser-assisted in situ keratomileusis (FS-LASIK) may compromise the retinal nerve fiber layer (RNFL), newer femtosecond platforms that operate without causing significant IOP elevation have been developed in recent years. However, this assumption has not been adequately tested. The aim of the current study was to evaluate possible changes in RFNL thickness in nonglaucomatous myopic patients undergoing FS-LASIK using the 60 KHz IntraLase® device that significantly elevates the IOP for an appreciable period of time vs an advanced surface ablation technique (laser-assisted subepithelial keratomileusis, LASEK) that does not induce any IOP elevation. Methods: This was a prospective, observational, controlled cohort study. One randomly selected eye of 114 consecutive eligible patients was analyzed. Inclusion criteria were myopia up to -6.00 diopters and astigmatism up to -2.00 diopters. As clinically indicated, 50 patients underwent LASEK and 64 underwent FS-LASIK. The RNFL thickness was determined with a spectral-domain optical coherence tomography device preoperatively and 3 months postoperatively by the same masked observer. Results: There was no significant difference in preoperative refractive error, age, or sex between the groups. Preoperatively, central corneal thickness was significantly lower in the LASEK group (529.1±36.1 vs 562.4±31.6 µm, P=0.001). For the LASEK group, there was no significant difference between preoperative and postoperative RNFL thickness in the studied sectors (superior-temporal, temporal, inferior-temporal, average). For the FS-LASIK group, compared to preoperative RNFL measures, statistically significant thicker postoperative values were found for the average RNFL (mean difference: 0.67 µm, 0.7% increase, P=0.008) and the inferior-temporal sector (mean difference: 0.92 µm, 0.6% increase, P=0.02). Conclusion: LASIK with a femtosecond platform that induces high intraoperative IOP did not cause RNFL thinning. The observed differences between preoperative and postoperative values are below the axial resolution limit of optical coherence tomography devices.Keywords
This publication has 30 references indexed in Scilit:
- Assessment of retinal ganglion cell damage in glaucomatous optic neuropathy: Axon transport, injury and soma lossExperimental Eye Research, 2015
- Comparison of 2 femtosecond lasers for flap creation in myopic laser in situ keratomileusis: One-year resultsJournal of Cataract & Refractive Surgery, 2015
- Femtosecond Lasers for LASIK Flap CreationOphthalmology, 2013
- In Vivo Real-Time Intraocular Pressure Variations during LASIK Flap CreationInvestigative Ophthalmology & Visual Science, 2010
- Ocular Rigidity, Ocular Pulse Amplitude, and Pulsatile Ocular Blood Flow: The Effect of Intraocular PressureInvestigative Ophthalmology & Visual Science, 2009
- Influence of Epi-LASIK and Alcohol-assisted LASEK on Retinal Nerve Fiber Layer ThicknessJournal of Refractive Surgery, 2007
- Porcine Model to Compare Real-Time Intraocular Pressure during LASIK with a Mechanical Microkeratome and Femtosecond LaserInvestigative Ophthalmology & Visual Science, 2007
- Effect of laser in situ keratomileusis on optic nerve head topography and retinal nerve fiber layer thicknessJournal of Cataract & Refractive Surgery, 2003
- Influence of LASIK on scanning laser polarimetric measurement of the retinal nerve fibre layer with fixed angle and customised corneal polarisation compensationBritish Journal of Ophthalmology, 2003
- Visual field defect associated with laser in situ keratomileusisAmerican Journal of Ophthalmology, 2000