Three-Dimensional Analysis of the Thermal Interaction of Multiple Vertical Ground Heat Exchangers
Authors:
- 27 March 2014
- journal article
- research article
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 12 (11) , 1144-1150
Abstract
The use of ground heat pumps for heating and cooling buildings is receiving increasing attention due to their many benefits. But such systems have some challenges regarding the long-term use of groundwater for thermal purposes, including the sustainability of the systems. Interference between adjoining installations is being reported, raising issues of sustainability in terms of performance and equitable sharing of natural resources. To help address this issue, an investigation is reported here of the thermal interaction of vertical ground heat exchangers, in which two- and three-dimensional transient heat conduction is examined in the soil around vertical ground heat exchangers. A finite volume numerical solution is applied using FLUENT software. The research extends a previous study in which the analytical results of the line source theory are validated using two-dimensional numerical results, which inherently neglects axial heat transfer effects. The three-dimensional numerical study reported here accounts for axial heat transfer in the soil surrounding a borehole. It is demonstrated that a specified length exists for which the heat from the borehole wall is only conducted in the radial direction and the results of the two-dimensional heat conduction approach are valid.Keywords
Funding Information
- Ontario Ministry of Environment
This publication has 11 references indexed in Scilit:
- A Numerical Model for the Simulation of a Vertical U-Bend Ground Heat Exchanger Used in a Ground-Coupled Heat PumpInternational Journal of Green Energy, 2014
- Examination of thermal interaction of multiple vertical ground heat exchangersApplied Energy, 2012
- Evaluation of heat exchange rate of GHE in geothermal heat pump systemsRenewable Energy, 2009
- A two-region simulation model of vertical U-tube ground heat exchanger and its experimental verificationApplied Energy, 2009
- Development of a numerical model for the simulation of vertical U-tube ground heat exchangersApplied Thermal Engineering, 2009
- Computer simulation of borehole ground heat exchangers for geothermal heat pump systemsRenewable Energy, 2008
- Analytical and semi-analytical solutions for short-time transient response of ground heat exchangersEnergy and Buildings, 2008
- A new contribution to the finite line-source model for geothermal boreholesEnergy and Buildings, 2007
- Improvement in Modeling of Heat Transfer in Vertical Ground Heat ExchangersHVAC&R Research, 2004
- A Multiple Load Aggregation Algorithm for Annual Hourly Simulations of GCHP SystemsHVAC&R Research, 2004