Deep learning MR reconstruction in knees and ankles in children and young adults. Is it ready for clinical use?
- 8 August 2024
- journal article
- research article
- Published by Springer Nature in Skeletal Radiology
- Vol. 54 (3) , 509-529
Abstract
Objective To evaluate the diagnostic performance and image quality of accelerated Turbo Spin Echo sequences using deep-learning (DL) reconstructions compared to conventional sequences in knee and ankle MRIs of children and young adults. Materials and methods IRB-approved prospective study consisting of 49 MRIs from 48 subjects (10 males, mean age 16.4 years, range 7–29 years), with each MRI consisting of both conventional and DL sequences. Sequences were evaluated blindly to determine predictive values, sensitivity, and specificity of DL sequences using conventional sequences and knee arthroscopy (if available) as references. Physeal patency and appearance were evaluated. Qualitative parameters were compared. Presence of undesired image alterations was assessed. Results The prevalence of abnormal findings in the knees and ankles were 11.7% (75/640), and 11.5% (19/165), respectively. Using conventional sequences as reference, sensitivity and specificity of DL sequences in knees were 90.7% and 99.3%, and in ankles were 100.0% and 100.0%. Using arthroscopy as reference, sensitivity and specificity of DL sequences were 80.0% and 95.8%, and of conventional sequences were 80.0% and 97.9%. Agreement of physeal status was 100.0%. DL sequences were qualitatively “same-or-better” compared to conventional (p < 0.032), except for pixelation artifact for the PDFS sequence (p = 0.233). No discrete image alteration was identified in the knee DL sequences. In the ankle, we identified one DL artifact involving a tendon (0.8%, 1/125). DL sequences were faster than conventional sequences by a factor of 2 (p < 0.001). Conclusion In knee and ankle MRIs, DL sequences provided similar diagnostic performance and “same-or-better” image quality than conventional sequences at half the acquisition time.Keywords
This publication has 43 references indexed in Scilit:
- Motion artifacts in MRI: A complex problem with many partial solutionsJournal of Magnetic Resonance Imaging, 2015
- Diagnostic performance of magnetic resonance imaging and pre-surgical evaluation in the assessment of traumatic intra-articular knee disorders in children and adolescents: what conditions still pose diagnostic challenges?Pediatric Radiology, 2014
- Fast-sequence MRI studies for surveillance imaging in pediatric hydrocephalusJournal of neurosurgery. Pediatrics, 2014
- Investigating the quantitative fidelity of prospectively undersampled chemical shift imaging in muscular dystrophy with compressed sensing and parallel imaging reconstructionMagnetic Resonance in Medicine, 2013
- Safety in pediatric imaging: an updateActa Radiologica, 2013
- Contrast-enhanced Magnetic Resonance Imaging in Pediatric Patients: Review and Recommendations for Current PracticeMagnetic Resonance Insights, 2013
- Measuring signal‐to‐noise ratio in partially parallel imaging MRIMedical Physics, 2011
- Paediatric MRI under sedation: is it necessary? What is the evidence for the alternatives?Pediatric Radiology, 2011
- Translational Research in RadiologyAcademic Radiology, 2009
- Pediatric musculoskeletal MRI: basic principles to optimize successPediatric Radiology, 2007