Abstract
This paper presents elements of seismic design for jointed precast cantilever wall units designed to rock about their foundation. Gravity loading and prestressed unbonded tendons provide the restoring force in these walls. Lateral displacements eventually result in a separation gap forming only at the wall-foundation beam connection. The gap reduces the wall stiffness and results in nonlinear response. Design of these walls is made with the explicit objective of ensuring a self-centering response. That is, the wall returns to its pre-earthquake position upon unloading from a large displacement excursion. The integrity of the walls is maintained because no plastic hinges form and there are no residual postearthquake displacements. Energy dissipators, in the way of longitudinal mild steel reinforcement crossing the joint between the walls and the foundation, are incorporated into these walls to add significant energy dissipation capacity while preserving the self-centering response. This paper also describe...