Microfluidic biosensor for cholera toxin detection in fecal samples
- 24 June 2014
- journal article
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 407 (3) , 727-736
Abstract
Sample preparation and processing steps are the most critical assay aspects that require our attention in the development of diagnostic devices for analytes present in complex matrices. In the best scenarios, diagnostic devices should use only simple sample processing. We have therefore investigated minimal preparation of stool samples and their effect on our sensitive microfluidic immunosensor for the detection of cholera toxin. This biosensor was previously developed and tested in buffer solutions only, using either fluorescence or electrochemical detection strategies. The microfluidic devices were made from polydimethylsiloxane using soft lithography and silicon templates. Cholera toxin subunit B (CTB)-specific antibodies immobilized onto superparamagnetic beads and ganglioside GM1-containing liposomes were used for CTB recognition in the detection system. Quantification of CTB was tested by spiking it in human stool samples. Here, optimal minimal sample processing steps, including filtration and centrifugation, were optimized using a microtiter plate assay owing to its high-throughput capabilities. Subsequently, it was transferred to the microfluidic systems, enhancing the diagnostic characteristic of the biosensor. It was found that the debris removal obtained through simple centrifugation resulted in an acceptable removal of matrix effects for the fluorescence format, reaching a limit of detection of only 9.0 ng/mL. However, the electron transfer in the electrochemical format was slightly negatively affected (limit of detection of 31.7 ng/mL). Subsequently, cross-reactivity using the heat-labile Escherichia coli toxin was investigated using the electrochemical microfluidic immunosensors and was determined to be negligible. With minimal sample preparation required, these microfluidic liposome-based systems have demonstrated excellent analytical performance in a complex matrix and will thus be applicable to other sample matrices.Keywords
This publication has 32 references indexed in Scilit:
- Microfluidic electrochemical immunoarray for ultrasensitive detection of two cancer biomarker proteins in serumBiosensors and Bioelectronics, 2011
- Automated microsystem for electrochemical detection of cancer markersElectrophoresis, 2011
- Citrinin (CIT) determination in rice samples using a micro fluidic electrochemical immunosensorTalanta, 2011
- EIS microfluidic chips for flow immunoassay and ultrasensitive cholera toxin detectionLab on a Chip, 2010
- Microfluidic-based biosensors toward point-of-care detection of nucleic acids and proteinsMicrofluidics and Nanofluidics, 2010
- Microchip-based ELISA strategy for the detection of low-level disease biomarker in serumAnalytica Chimica Acta, 2009
- Multiplexed Detection of Bacteria and Toxins Using a Microflow CytometerAnalytical Chemistry, 2009
- Microfluidic immunosensor for rapid and sensitive detection of bovine viral diarrhea virusSensors and Actuators B: Chemical, 2009
- On-chip detection of myoglobin based on fluorescenceBiosensors and Bioelectronics, 2009
- Development of a microfluidic biosensor module for pathogen detectionLab on a Chip, 2005