Suture Tape With Broad Full‐Width Core Versus Traditional Round Suture With Round Core: A Mechanical Comparison
- 1 August 2019
- journal article
- research article
- Published by Wiley in Arthroscopy
- Vol. 35 (8) , 2461-2466
Abstract
Purpose: To compare the inherent mechanical properties of suture in tape configuration with a flat, evenly distributed core to a round suture with a round core composed of the same materials. Methods: SutureTape and FiberWire composed of equivalent materials were used to tie surgical knots. Knot height was measured. Knot security was measured at the maximum load at 1, 2, and 3 mm of displacement and at failure. Tensile strength and stiffness were measured using untied samples. Results: SutureTape demonstrated superior knot security with greater ultimate load to failure (327.2 ± 15.4 N vs 257.4 ± 12.2 N; P = .002), maximum load at 1 mm of displacement (149.8 ± 18.6 N vs 108.8 ± 13.8 N; P = .001), and 2 mm of displacement (242.7 ± 38.6 N vs 181.2 ± 24.4 N; P = .008). It also demonstrated greater stiffness (5.4 ± 0.3 N/mm vs 2.8 ± 0.3 N/mm; P < .001) and tensile strength (378.8 ± 13.6 N vs 235.6 ± 4.8 N). Knot height differences (1.27 ± .11 mm vs 1.37 ± .08 mm; P = .110) and load at 3 mm of displacement (279.3 ± 42.4 N vs 225.5 ± 46.1 N; P = .062) were not statistically significant. Conclusions: During mechanical testing, SutureTape with a broad core distributed over the full width of the tape demonstrated greater knot security, ultimate load to failure, and tensile stiffness than FiberWire, a round core suture. We found no significant difference in knot stack height between the suture designs. Clinical Relevance: The study demonstrates the superior mechanical properties of suture in tape configuration over similarly composed round suture without a significant difference in knot stack height. Suture in tape configuration has the potential to perform as well as round suture in the clinical setting.Keywords
Funding Information
- Orthopaedic Technologies
This publication has 30 references indexed in Scilit:
- Initial Loop and Knot Security of Arthroscopic Knots Using High‐Strength SuturesArthroscopy, 2007
- Mechanical and Handling Properties of Braided Polyblend Polyethylene Sutures in Comparison to Braided Polyester and Monofilament Polydioxanone SuturesArthroscopy, 2006
- The Arthroscopic Square Knot: A Biomechanical Comparison With Open and Arthroscopic KnotsArthroscopy, 2006
- Comparison and Performance Characteristics of 3 Different Knots When Tied With 2 Suture Materials Used for Shoulder ArthroscopyArthroscopy, 2006
- Arthroscopic knot tying: The role of instrumentation in achieving knot securityArthroscopy, 2005
- Arthroscopic knots: Determining the optimal balance of loop security and knot securityArthroscopy, 2004
- Cyclic testing of arthroscopic knot securityArthroscopy, 2004
- Effect of suture knot location on tensile strength after flexor tendon repairThe Journal of Hand Surgery, 1996
- Effect of Suture Knots on Tensile Strength of Repaired Canine Flexor TendonsJournal of Hand Surgery (European Volume), 1995
- Tensile strength of suture materialsJournal of Biomedical Materials Research, 1985