SIMS imaging studies of the corrosion of alloy 800 and alloy 600 surfaces under secondary side boiler conditions
Authors:
- 1 August 1992
- journal article
- Published by Wiley in Surface and Interface Analysis
- Vol. 18 (8) , 601-603
Abstract
The nickel‐rich superalloys Alloy 600 and Alloy 800 have been corroded in mildly alkaline deuterated aqueous conditions typical of secondary coolant circuits in a nuclear power station. The oxide films and substrates of these alloys have been analysed by imaging SIMS depth profiling, which makes it possible to describe elemental distribution in all three dimensions. The measurement of the distribution of the secondary ions NiO − , FeO − and CrO − appears useful for detailing the behaviour of nickel, iron and chromium within oxidized phases. The measurement of D − distribution outlines the extent of oxide hydration. For Alloy 800, evidence of sodium migration into the grain boundaries of the alloy substrate is found. For Alloy 600, no grain boundary sodium ingress can be identified under comparable corrosion conditions.Keywords
This publication has 2 references indexed in Scilit:
- Study of tinplate structure using imaging secondary ion spectrometrySurface and Interface Analysis, 1991
- X‐Ray Photoelectron Studies of the Aqueous Oxidation of Inconel‐600 AlloyJournal of the Electrochemical Society, 1979