Wearable Pulse Wave Monitoring System Based on MEMS Sensors
Open Access
- 23 February 2018
- journal article
- research article
- Published by MDPI AG in Micromachines
- Vol. 9 (2) , 90
Abstract
Pulse wave monitoring is critical for the evaluation of human health. In this paper, a wearable multi-sensor pulse wave monitoring system is proposed and demonstrated. The monitoring system consists of a measuring unit and an analog circuit processing unit. The main part of the measuring unit is a flexible printed circuit board (PCB) with a thickness of 0.15 mm, which includes three micro-electromechanical system (MEMS) pressure sensors softly packaged by polydimethylsiloxane (PDMS), a blood oxygen detector and a MEMS three-axis accelerometer. The MEMS pressure sensors,the blood oxygen detector and the accelerometer are fixed on the expected locations of the flexible PCB. The analog circuit processing unit includes a power supply module, a filter and an amplifier. The pulse waves of two volunteers are detected by the monitoring system in this study. The output signals of the analog circuit processing module are processed and analyzed. In the preliminary test, the time delay of the three pressure pulse waves has been detected and the calculated pulse wave velocities (PWVs) are 12.50 and 11.36 m/s, respectively. The K value, related to the area of the pulse wave, can be obtained. Both the PWV and K value meet the health parameter standards.Keywords
Funding Information
- Shenzhen Science and Technology Research and Development Funds (JCYJ20150831192244849, JCYJ20160411164305110)
- National High Technology Research and Development Plan of China (2015AA043505)
This publication has 13 references indexed in Scilit:
- A survey on signals and systems in ambulatory blood pressure monitoring using pulse transit timePhysiological Measurement, 2015
- Skin-Coupled Personal Wearable Ambulatory Pulse Wave Velocity Monitoring System Using Microelectromechanical SensorsIEEE Sensors Journal, 2014
- Validation of blood pressure monitoring using pulse transit time in heart failure patients with Cheyne–Stokes respiration undergoing adaptive servoventilation therapySleep and Breathing, 2013
- A real time, wearable ECG and continous blood pressure monitoring system for first responders2011
- Adaptive hydrostatic blood pressure calibration: Development of a wearable, autonomous pulse wave velocity blood pressure monitor2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2007
- Measurement of Local Pulse Wave Velocity: Effects of Signal Processing on PrecisionUltrasound in Medicine & Biology, 2007
- Adaptive blood pressure estimation from wearable PPG sensors using peripheral artery pulse wave velocity measurements and multi-channel blind identification of local arterial dynamics2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), 2006
- Aortic pulse wave velocity index and mortality in end-stage renal diseaseKidney International, 2003
- Aortic Pulse-Wave Velocity and Its Relationship to Mortality in Diabetes and Glucose IntoleranceCirculation, 2002
- Assessment of Arterial Distensibility by Automatic Pulse Wave Velocity MeasurementHypertension, 1995