Microdroplet and spatter contamination during phacoemulsification cataract surgery in the era ofCOVID-19
Open Access
- 1 December 2020
- journal article
- research article
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 48 (9) , 1168-1174
Abstract
Importance Determine phacoemulsification cataract surgery risk in a Covid-19 era. Background SARS-CoV-2 (Covid-19) transmission via microdroplet and aerosol-generating procedures presents risk to medical professionals. As the most common elective surgical procedure performed globally; determining contamination risk from phacoemulsification cataract surgery may guide personal protection equipment use. Design Pilot study involving phacoemulsification cataract surgery on enucleated porcine eyes by experienced ophthalmologists in an ophthalmic operating theatre. Participants Two ophthalmic surgical teams. Methods Standardized phacoemulsification of porcine eyes by two ophthalmologists accompanied by an assistant. Fluorescein incorporated into phacoemulsification irrigation fluid identifying microdroplets and spatter. Contamination documented using a single-lens reflex camera with a 532 nm narrow bandpass (fluorescein) filter, in-conjunction with a wide-field blue light and flat horizontal laser beam (wavelength 532 nm). Quantitative image analysis using Image-J software. Main Outcome Measures Microdroplet and spatter contamination from cataract phacoemulsification. Results With phacoemulsification instruments fully within the eye, spatter contamination was limited to 16 cm below the neckline in surgeon 1 and > 5.5 cm below the neckline of surgeon 2. A small tear in the phacoemulsification irrigation sleeve, presented a worse-case scenario the greatest spatter. No contamination above the surgeons' neckline nor contamination of assistant occurred. Conclusions and Relevance Cataract phacoemulsification generates microdroplets and spatter. Until further studies on SARS-CoV-2 transmission via microdroplets or aerosolisation of ocular fluid are reported, this pilot study only supports standard personal protective equipment.Keywords
This publication has 21 references indexed in Scilit:
- The presence and impact of herpes virus DNA in recipient cornea and aqueous humor on graft survival following penetrating keratoplastyJournal of the Formosan Medical Association, 2020
- Revisiting the dangers of the coronavirus in the ophthalmology practiceEye, 2020
- Healthcare worker exposure to Middle East respiratory syndrome coronavirus (MERS-CoV): Revision of screening strategies urgently neededInternational Journal of Infectious Diseases, 2018
- Dissemination of aerosol and splatter during ultrasonic scaling: A pilot studyJournal of Infection and Public Health, 2015
- Rising Cataract Surgery Rates: Demand and SupplyOphthalmology, 2014
- The severe acute respiratory syndrome coronavirus in tearsBritish Journal of Ophthalmology, 2004
- Contamination during removal of cement in revision hip arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2003
- New phacoemulsification technologiesJournal of Cataract & Refractive Surgery, 2002
- Association of herpesviruses in the aqueous humor of patients with serpiginous choroiditis: a polymerase chain reaction-based studyOcular Immunology and Inflammation, 2002
- Studies on Dental Aerobiology: I. Bacterial Aerosols Generated during Dental ProceduresJournal of Dental Research, 1969