Comparison of Near-Infrared Spectroscopy and Somatosensory Evoked Potentials for the Detection of Cerebral Ischemia During Carotid Endarterectomy
Authors:
- 1 October 1998
- journal article
- research article
- Published by Wolters Kluwer Health in Stroke
- Vol. 29 (10) , 2032-2037
Abstract
Background and Purpose —We sought to assess the clinical value of regional cerebral saturation (rS o 2 ) obtained by means of the cerebral oximeter INVOS 3100A (Somanetics) in comparison to monitoring of somatosensory evoked potentials (SEP) for the reliable detection of severe cerebral ischemia requiring shunt placement in the individual patient undergoing carotid surgery under general anesthesia. Methods —In 317 patients undergoing reconstructive surgery on the internal carotid artery, simultaneous recordings of SEP and rS o 2 were obtained throughout the operation. Results —All 287 patients with preserved cortical SEP remained neurologically intact. Shunt placement was performed in 27 patients (9%) after flattening of cortical SEP during cross-clamping of the internal carotid artery. A stable rS o 2 value just before cross-clamping and the lowest value after cross-clamping were registered, and the decrease was calculated. A statistically significant ( P 2 after cross-clamping could be found in patients without (64.9±8.3% to 60.9±9.9%) as well as in patients with consecutive loss of cortical SEP (65.8±9.1% to 56.1±13.4%). The difference of the decrease of rS o 2 in both groups was highly significant (6.9±9.0% versus 15.6±14.0%; P 2 and derived change of rS o 2 did not allow the definition of a threshold value indicating need of shunt placement. Conclusions —The reliability of SEP for the detection of clamp-related hypoperfusion has been reaffirmed. As long as rS o 2 threshold values indicating critical cerebral ischemia are not defined, therapeutic interventions based on monitoring with the cerebral oximeter INVOS 3100A are not justified.Keywords
This publication has 31 references indexed in Scilit:
- Anesthesia for Carotid EndarterectomyJournal of Neurosurgical Anesthesiology, 1997
- Cerebral Hemoglobin and Optical Pathlength Influence Near-Infrared Spectroscopy Measurement of Cerebral Oxygen SaturationAnesthesia & Analgesia, 1997
- A comparison of the Invos 3100 and the Critikon 2020 near‐infrared spectrophotometers as monitors of cerebral oxygenationAnaesthesia, 1997
- The contribution of extracranial blood oxygenation on near‐infrared spectroscopy during carotid thrombendarterectomyAnaesthesia, 1997
- Combined Transcranial Doppler and Electrophysiologic Monitoring for Carotid EndarterectomyJournal of Neurosurgical Anesthesiology, 1997
- Cerebral Near-Infrared SpectroscopyAnesthesia & Analgesia, 1996
- Cerebral oximetry: a useful monitor during carotid artery surgeryAnaesthesia, 1995
- The effect of overlying tissue on the spatial sensitivity profile of near-infrared spectroscopyPhysics in Medicine & Biology, 1995
- A comparative study of two near infrared spectrophotometers for the assessment of cerebral haemodynamicsActa Anaesthesiologica Scandinavica, 1995
- Technical Issues in Carotid Artery Surgery 1995Neurosurgery, 1995