Thermal Vacuum and Swivel Table Tests of a CMG and Fault Mechanism Analysis
- 1 September 2018
- journal article
- research article
- Published by American Society of Civil Engineers (ASCE) in Journal of Aerospace Engineering
- Vol. 31 (5)
Abstract
Thermal vacuum and swivel table tests of a control moment gyroscope (CMG) are designed and the start-up hesitation and rotation break of the CMG are analyzed. In order to study the fault mechanism, a thermo-structural coupling simulation was performed on the CMG under the temperature conditions of 60°C and approximately 20°C, as well as the static and dynamic working conditions of the swivel table and gimbal. The simulation results show that the main reason for the start-up hesitation and rotation break of the gimbal is an elliptical deformation in different circumferential positions of the gimbal shell and the gimbal bearing. Under certain combinations of temperature and dynamic conditions, the shrinkage of the radial and axial clearances of the gimbal bearing causes the faults, which is consistent with the test results. The test and simulation results are also helpful in determining the temperature limits of the CMG under different conditions and can help improve their thermal design.Keywords
This publication has 7 references indexed in Scilit:
- Design, Manufacturing, and Ground Testing of a Control-Moment Gyro for Agile MicrosatellitesJournal of Aerospace Engineering, 2017
- Development of a low-cost, low micro-vibration CMG for small agile satellite applicationsActa Astronautica, 2017
- The Contact Analysis for Deep Groove Ball Bearing Based on ANSYSProcedia Engineering, 2011
- Impact of geometrical defects on bearing assemblies with integrated raceways in aeronautical gearboxesMechanism and Machine Theory, 2008
- Precision Attitude Control of Spacecraft with Control Moment Gyros2006
- Operating temperatures in mist lubricated rolling element bearings for gas turbines2002
- Torque amplification of control moment gyrosElectronics Letters, 2002