LSPR and Interferometric Sensor Modalities Combined Using a Double-Clad Optical Fiber
Open Access
Abstract
We report on characterization of an optical fiber-based multi-parameter sensor concept combining localized surface plasmon resonance (LSPR) signal and interferometric sensing using a double-clad optical fiber. The sensor consists of a micro-Fabry-Perot in the form of a hemispherical stimuli-responsive hydrogel with immobilized gold nanorods on the facet of a cleaved double-clad optical fiber. The swelling degree of the hydrogel is measured interferometrically using the single-mode inner core, while the LSPR signal is measured using the multi-mode inner cladding. The quality of the interferometric signal is comparable to previous work on hydrogel micro-Fabry-Perot sensors despite having gold nanorods immobilized in the hydrogel. We characterize the effect of hydrogel swelling and variation of bulk solution refractive index on the LSPR peak wavelength. The results show that pH-induced hydrogel swelling causes only weak redshifts of the longitudinal LSPR mode, while increased bulk refractive index using glycerol and sucrose causes large blueshifts. The redshifts are likely due to reduced plasmon coupling of the side-by-side configuration as the interparticle distance increases with increasing swelling. The blueshifts with increasing bulk refractive index are likely due to alteration of the surface electronic structure of the gold nanorods donated by the anionic polymer network and glycerol or sucrose solutions. The recombination of biotin-streptavidin on gold nanorods in hydrogel showed a 7.6 nm redshift of the longitudinal LSPR. The LSPR response of biotin-streptavidin recombination is due to the change in local refractive index (RI), which is possible to discriminate from the LSPR response due to changes in bulk RI. In spite of the large LSPR shifts due to bulk refractive index, we show, using biotin-functionalized gold nanorods binding to streptavidin, that LSPR signal from gold nanorods embedded in the anionic hydrogel can be used for label-free biosensing. These results demonstrate the utility of immobilizing gold nanorods in a hydrogel on a double-clad optical fiber-end facet to obtain multi-parameter sensing.Keywords
This publication has 32 references indexed in Scilit:
- [INVITED] Tilted fiber grating mechanical and biochemical sensorsOptics & Laser Technology, 2016
- Optical waveguide modeling of refractive index mediated pH responses in silica nanocomposite thin film based fiber optic sensorsJournal of Applied Physics, 2016
- Novel silica surface charge density mediated control of the optical properties of embedded optically active materials and its application for fiber optic pH sensing at elevated temperaturesNanoscale, 2014
- Dip Biosensor Based on Localized Surface Plasmon Resonance at the Tip of an Optical FiberLangmuir, 2014
- Size Matters: Problems and Advantages Associated with Highly Miniaturized SensorsSensors, 2012
- Tilted fiber Bragg grating sensorsLaser & Photonics Reviews, 2012
- Determination of Glucose Levels Using a Functionalized Hydrogel−Optical Fiber Biosensor: Toward Continuous Monitoring of Blood Glucose in VivoAnalytical Chemistry, 2009
- Determination of Swelling of Responsive Gels with Nanometer Resolution. Fiber-Optic Based Platform for Hydrogels as Signal TransducersAnalytical Chemistry, 2008
- Optical‐fiber bundlesThe FEBS Journal, 2007
- Solvent and Ligand Effects on the Localized Surface Plasmon Resonance (LSPR) of Gold ColloidsThe Journal of Physical Chemistry B, 2004