Development and application of a quality control procedure for short-wave diathermy units
- 1 January 2003
- journal article
- research article
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 41 (1) , 62-68
Abstract
Short-wave diathermy (SWD) is a form of radiofrequency (RF) radiation, operating at 27.12 MHz, that is used therapeutically by physiotherapists. Although this form of therapy is widely available, the management of the equipment is not often addressed by either physiotherapists or by medical physics/clinical engineering. A quality control protocol for SWD units, examining power output and electrical and mechanical condition, was developed and applied to 20 units used in clinical practice. In addition, an environmental assessment of where the units were used was also included. Results showed that the power output was generally stable (coefficient of variation range 0–8.8%) and reproducible (coefficient of variation range 0–6.8%). When the outputs from 12 similar units were compared, it was found that the relationship between the units' intensity settings and power output measurements was non-linear. Two units with mechanical timers were found to have inaccuracies that could contribute, under a ‘worst-case’ scenario, to a dosage error of up to 45%. Environmental analysis found that all treatment plinths in use contained metal parts, which could constitute a fire hazard, and no department examined was equipped with an RF screened room, a facility that would ensure that other persons in the vicinity were not exposed to excessive stray radiation.Keywords
This publication has 11 references indexed in Scilit:
- Short-wave diathermy in Irish physiotherapy departmentsBritish Journal of Therapy and Rehabilitation, 2001
- Short-Wave Diathermy: A Review of Existing Clinical TrialsPhysical Therapy Reviews, 2001
- A Survey of Electrotherapeutic Modalities: Ownership and Use in the NHS in EnglandPhysiotherapy, 1995
- Guidelines for the Safe Use of Pulsed Shortwave Therapy EquipmentPhysiotherapy, 1994
- A Simple Calorimeter for Monitoring the Output Power of Ultrasound Therapy MachinesPhysiotherapy, 1994
- The performance of ultrasound physiotherapy machines in Lothian region, Scotland, 1992Ultrasound in Medicine & Biology, 1994
- Guide Lines for the Safe Use of Continuous Shortwave Therapy Equipment Safety of Electrotherapy Equipment Working GroupPhysiotherapy, 1992
- A Calibration Survey of Physiotherapy Ultrasound Equipment in North WalesPhysiotherapy, 1988
- Guidelines on limits of exposure to radiofrequency electromagnetic fields in the frequency range from 100 kHz to 300 GHz. International Non-Ionizing Radiation Committee of the International Radiation Protection Association.1988
- Evaluation report: Shortwave therapy unitsJournal of Medical Engineering & Technology, 1987