Quantitative myocardial contrast echocardiography: a new method for the non-invasive detection of chronic heart transplant rejection
Authors:
- S. F. de MarchiSMS. F. de Marchi
- P. RoelliPRP. Roelli
- S. GloeklerSGS. Gloekler
- T. TraupeTTT. Traupe
- H. SteckHSH. Steck
- P. EshtehardiPEP. Eshtehardi
- S. CookSCS. Cook
- R. VogelRVR. Vogel
- P. MohacsiPMP. Mohacsi
- C. SeilerCSC. Seiler
- 23 April 2013
- journal article
- clinical trial
- Published by Oxford University Press (OUP) in European Heart Journal - Cardiovascular Imaging
- Vol. 14 (12) , 1187-1194
Abstract
Chronic heart transplant rejection, i.e. cardiac allograft vasculopathy (CAV) is a major adverse prognostic factor after heart transplantation (HTx). This study tested the hypothesis that the relative myocardial blood volume (rBV) as quantified by myocardial contrast echocardiography accurately detects severe CAV as defined by coronary intravascular ultrasound (IVUS). Forty-five HTx patients underwent a total of 50 quantitative IVUS measurements for intima thickness assessment (>1 mm = severe CAV; the reference method). Simultaneously, the two factors constituting myocardial perfusion (mL/min/g) were obtained by transthoracic contrast echocardiography at rest: rBV (the test method), a measure of microvascular density (mL/mL), and its exchange rate β (1/s; a measure of coronary conductance) after mechanical contrast bubble disruption.Sixty-nine per cent (31 of 45) of the HTx patients showed severe CAV. rBV at rest was equal to 0.17 ± 0.05 in the group without severe CAV, and it was equal to 0.12 ± 0.07 in the group with severe CAV (P = 0.0157). Conversely, β amounted to 6.4 ± 4.5 in the former and to 10.3 ± 6.2 in the latter group (P = 0.0410), thus, maintaining normal resting myocardial perfusion at 1 mL/min/g. IVUS determined intima thickness correlated significantly and inversely with rBV at rest. An rBV value at rest 1 mm): area under the receiver operating characteristics curve = 0.844, P = 0.004, sensitivity = 0.90, specificity = 0.75. Severe CAV can be detected using the non-invasive method of quantitative myocardial contrast echocardiography. rBV at rest amounting to 1 mm as determined invasively by IVUS. NCT00414895.Keywords
This publication has 16 references indexed in Scilit:
- Coronary collateral function in the transplanted heart: propensity score matching with coronary artery diseaseHeart, 2011
- International Society for Heart and Lung Transplantation working formulation of a standardized nomenclature for cardiac allograft vasculopathy—2010The Journal of Heart and Lung Transplantation, 2010
- Assessment of Microcirculatory Remodeling With Intracoronary Flow Velocity and Pressure MeasurementsCirculation, 2009
- Registry of the International Society for Heart and Lung Transplantation: Twenty-sixth Official Adult Heart Transplant Report—2009The Journal of Heart and Lung Transplantation, 2009
- Survival Beyond 10 Years Following Heart Transplantation: The Cleveland Clinic Foundation ExperienceTransplantation Proceedings, 2005
- Multicenter Intravascular Ultrasound Validation Study Among Heart Transplant RecipientsJACC, 2005
- Intravascular Ultrasound Evidence of Angiographically Silent Progression in Coronary Atherosclerosis Predicts Long-Term Morbidity and Mortality After Cardiac TransplantationJACC, 2005
- The quantification of absolute myocardial perfusion in humans by contrast echocardiographyJACC, 2005
- Effects of time and previous acute rejection episodes on coronary vascular reserve in human heart transplant recipientsJACC, 1992
- Intracoronary ultrasound in cardiac transplant recipients. In vivo evidence of "angiographically silent" intimal thickening.Circulation, 1992