Abstract
The PlusOptix photoscreeners (PlusOptix GmbH, Nuremberg, Germany) is used in many vision screening programs. The purpose of the present study was to further explore the accuracy of the PlusOptix A09 photoscreener in children with ametropia (myopia or hyperopia). A total of 70 eyes (35 children) were prospectively included. Before administration with the cycloplegia treatment 1 % cyclopentolate hydrochloride, children underwent refraction measurement with the PlusOptix A09. A refraction was then performed after cycloplegia with either Retinomax hand-held or Nidek autorefractor before and after 3 years old, respectively. The median (interquartile range) age was 58 (18 to 86) months. The mean (SD) spherical equivalent differed between PlusOptix A09 and cycloplegic autorefraction (+0.54 [1.82] D vs +1.06 [2.04] D, p = 0.04). PlusOptix A09 refraction was positively correlated with cycloplegic autorefraction (r = 0.81, p < 0.001) with higher coefficient in myopic than in hyperopic children (r = 0.91, p = 0.0002 and r = 0.52, p = 0.01, respectively). The mean (SD) difference between PlusOptix A09 and cycloplegic autorefraction was higher with hyperopia than myopia (0.73 [1.34] vs 0.05 [0.66], p = 0.01). The proportion of children with < 1-D difference between cycloplegic and PlusOptix A09 refraction was 68.8 %, higher with myopia than hyperopia (90 % vs 54.5 %, p = 0.01). The spherical equivalent value with non-cycloplegic PlusOptix A09 refraction is closer to that with cycloplegic autorefraction than non-cycloplegic autorefraction. The PlusOptix A09 photoscreener underestimated the hyperopia of 0.73 D and slightly overestimated myopia of 0.05 D. The PlusOptix A09 could be used for screening with higher accuracy in myopic than hyperopic children.Keywords
This publication has 18 references indexed in Scilit:
- A comparison of the Plusoptix S08 photorefractor to retinoscopy and cycloretinoscopyClinical and Experimental Optometry, 2013
- The accuracy of the plusoptiX A08 photoscreener in detecting risk factors for amblyopia in central IowaJournal of American Association for Pediatric Ophthalmology and Strabismus, 2013
- Screening for amblyopia risk factors in pre-verbal children using the Plusoptix photoscreener: a cross-sectional population-based studyBritish Journal of Ophthalmology, 2011
- Screening for refractive errors in children: The plusoptiX S08 and the Retinomax K-plus2 performed by a lay screener compared to cycloplegic retinoscopyJournal of American Association for Pediatric Ophthalmology and Strabismus, 2010
- Performance of the plusoptiX S04 photoscreener for the detection of amblyopia risk factors in children aged 3 to 5Journal of American Association for Pediatric Ophthalmology and Strabismus, 2010
- Field testing of the plusoptiX S04 photoscreenerJournal of American Association for Pediatric Ophthalmology and Strabismus, 2009
- Vision screening in children by Plusoptix Vision Screener compared with gold-standard orthoptic assessmentBritish Journal of Ophthalmology, 2008
- Plusoptix Vision Screener: the accuracy and repeatability of refractive measurements using a new autorefractorBritish Journal of Ophthalmology, 2008
- Performance of the Plusoptix vision screener for the detection of amblyopia risk factors in childrenJournal of American Association for Pediatric Ophthalmology and Strabismus, 2008
- A comparison of photorefraction and retinoscopy in childrenJournal of American Association for Pediatric Ophthalmology and Strabismus, 2007