Carbon Fiber Reinforced Polymer and Epoxy Adhesive Tensile Test Failure Analysis Using Scanning Electron Microscopy
Open Access
- 6 July 2017
- journal article
- research article
- Published by FapUNIFESP (SciELO) in Materials Research
- Vol. 20 (4) , 951-961
Abstract
Morphological characteristics analysis before and after tensile tests were studied using scanning electron microscopy (SEM) technique to follow the failure evolution on carbon fiber reinforced polymer (CFRP) and epoxy resins. Micrograph analysis of CFRP plate before tensile test shows some intrinsic manufacturing defects, which can influence the mechanical properties of the material. Micrograph analysis after tensile test shows that cracks propagation start in manufacturing defects, which lead the carbon fiber to be pulled out instead of breaking. Thus, cracks propagate through interfacial zones affecting the sharing force between matrix and carbon fiber. For the epoxies materials, the microscopy analysis showed that although epoxies adhesive have different phase distribution before tensile test, failure surfaces are described by fine granular particles covalent bonded with matrix, and the material fails in a brittle manner when the strength outstripped these bonds. Failure process for each material correlating the mechanical properties with the morphological characteristics of materials was discussed.Keywords
This publication has 21 references indexed in Scilit:
- Glass transition evaluation of commercially available epoxy resins used for civil engineering applicationsComposites Part B: Engineering, 2015
- Fatigue strengthening of damaged metallic beams using prestressed unbonded and bonded CFRP platesInternational Journal of Fatigue, 2012
- Structural behaviour of RC beams externally strengthened with FRP sheets under fatigue and monotonic loadingEngineering Structures, 2012
- Fatigue behavior of damaged steel beams repaired with CFRP stripsEngineering Structures, 2011
- Fracture mechanisms and failure analysis of carbon fibre/toughened epoxy composites subjected to compressive loadingComposite Structures, 2010
- Strengthening of old metallic structures in fatigue with prestressed and non-prestressed CFRP laminatesConstruction and Building Materials, 2009
- Debonding failure modes of flexural FRP-strengthened RC beamsComposites Part B: Engineering, 2008
- Behavior of Concrete Columns Confined by Fiber CompositesJournal of Structural Engineering, 1997
- The effect of the moisture absorption on the interfacial strength of polymeric matrix compositesJournal of Materials Science, 1995
- A fractographic analysis of delamination within multidirectional carbon/epoxy laminatesComposites Science and Technology, 1995