In Vitro Corrosion and in Vivo Response to Zinc Implants with Electropolished and Anodized Surfaces
Authors:
- Roger J. GuilloryRGRoger J. Guillory
- Malgorzata Sikora-JasinskaMSMalgorzata Sikora-Jasinska
- Jaroslaw W. DrelichJDJaroslaw W. Drelich
- Jeremy GoldmanJGJeremy Goldman
- 6 May 2019
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 11 (22) , 19884-19893
Abstract
Zinc (Zn)-based biodegradable metals have been widely investigated for cardiovascular stent and orthopedic applications. However, the effect of Zn surface features on adverse biological responses has not been well established. Here we hypothesized that a metallic zinc implant’s surface oxide film character may critically influence early neointimal growth and development. Electropolishing of surfaces has become the industry standard for metallic stents, while anodization of surfaces, although not practiced on stents at present, could increase thickness of stable oxide film and delay early-stage implant degradation. In this study, pure zinc samples were electropolished (EP) and anodized (AD) to engineer oxide films with distinctive physical and degradation characteristics, as determined by potentiodynamic polarization, electrochemical impedance spectroscopy and static immersion tests. The samples were then implanted within the aortic lumen of adult Sprague Dawley rats to determine the influence of surface engineering on biocompatibility responses to Zn implants. It was found that in vitro corrosion produced a porous corrosion layer for the EP samples and a densified layer on the AD samples. The AD material was more resistant to corrosion, while localized corrosion and pitting was seen on the EP surface. Interestingly, the increased variability from localized corrosion due to surface film character translated directly to the in vivo performance, where 100% of the AD implants but only 44% of the EP implants met the biocompatibility benchmarks. Overall, the results suggest that oxide films on degradable zinc critically affect early neointimal progression and overall success of degradable Zn materials.Keywords
Funding Information
- National Institute of Biomedical Imaging and Bioengineering (R21EB019118-01A1, R21EB024034-01A1)
- National Science Foundation
This publication has 47 references indexed in Scilit:
- Zinc Exhibits Ideal Physiological Corrosion Behavior for Bioabsorbable StentsAdvanced Materials, 2013
- Bioactive Titanium Oxide-Based Nanostructures Prepared by One-Step Hydrothermal AnodizationThe Journal of Physical Chemistry C, 2012
- Long‐term stability of self‐assembled monolayers on electropolished L605 cobalt chromium alloy for stent applicationsJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2011
- Aluminum Anodization in Oxalic Acid: Controlling the Texture of Al2O3/Al Monoliths for Catalytic AplicationsIndustrial & Engineering Chemistry Research, 2011
- Revolutionizing biodegradable metalsMaterials Today, 2009
- Electropolishing of Coronary StentsMaterials Science Forum, 2008
- Improved endothelial cell adhesion and proliferation on patterned titanium surfaces with rationally designed, micrometer to nanometer featuresActa Biomaterialia, 2008
- XPS study of the surface chemistry of conventional hot-dip galvanised pure Zn, galvanneal and Zn–Al alloy coatings on steelActa Materialia, 2003
- Interactions of CO 2 and CO at fractional atmosphere pressures with iron and iron oxide surfaces: one possible mechanism for surface contamination?Surface and Interface Analysis, 2002
- X‐ray photoelectron spectroscopy analysis of copper and zinc oxides and sulphidesSurface and Interface Analysis, 1992