Optical coherence tomography–derived corneal thickness asymmetry indices: Clinical reference study of normal eyes
- 1 October 2014
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 40 (10) , 1603-1609
Abstract
To determine 3-dimensional corneal pachymetry distribution characteristics in a large pool of healthy normal patients. Private practice, Athens, Greece. Prospective case series. Spectral-domain anterior segment optical coherence tomography (AS-OCT) was used for measurements of central (CCT) and minimum corneal thickness, thickness asymmetry indices for superonasal-inferotemporal (SN-IT) and superior-inferior (S-I), and focal thinning indices (Min-Med focal thinning, Min-Max thickness range). The study enrolled 561 eyes. The mean values were CCT, 537.17 μm ± 30.99 (SD) (range 447.0 to 654.0 μm); minimum corneal thickness, 529.01 ± 30.02 μm (range 435.0 to 644.0 μm); SN-IT, 26.32 ± 15.06 μm (range -23.0 to 97.0 μm); S-I, 25.34 ± 15.06 μm (range -36.0 to 93.0 μm); Min-Med, -20.70 ± 5.99 μm (range -7.0 to -50.0 μm); Min-Max, -59.79 ± 16.55 μm (range -156.0 to -23.0 μm). There were significant age-related differences; the mean SN-IT was 22.19 ± 12.40 μm (range -6.0 to 63.0 μm) in the younger group and 30.44 ± 15.07 μm (range -4.0 to 97.0 μm) in the older group (P=.002). The mean S-I was 21.47 ± 12.92 μm (range -5.0 to 70.0 μm) and 29.76 ± 16.27 μm (range -8.0 to 93.0 μm), respectively (P=.001). Corneal-thickness asymmetry distribution in a healthy eye population obtained by Fourier-domain AS-OCT showed increased asymmetry in the older group; the asymmetry was not sex dependent. These findings may provide a benchmark for future comparative studies. Dr. Kanellopoulos is a consultant to Alcon Laboratories, Inc., Allergan, Inc., Avedro, Inc., Keramed, Inc., and i-Optics. No other author has a financial or proprietary interest in any material or method mentioned.Keywords
This publication has 18 references indexed in Scilit:
- Fourier-Domain Optical Coherence Tomography Imaging in KeratoconusOphthalmology, 2013
- SD-OCT Analysis of Regional Epithelial Thickness Profiles in Keratoconus, Postoperative Corneal Ectasia, and Normal EyesJournal of Refractive Surgery, 2013
- Reliability and repeatability of swept-source Fourier-domain optical coherence tomography and Scheimpflug imaging in keratoconusJournal of Cataract & Refractive Surgery, 2012
- Novel Pachymetric Parameters Based on Corneal Tomography for Diagnosing KeratoconusJournal of Refractive Surgery, 2011
- Corneal topographic analysis in patients with keratoconus using 3-dimensional anterior segment optical coherence tomographyJournal of Cataract & Refractive Surgery, 2011
- Keratoconus Diagnosis with Optical Coherence Tomography Pachymetry MappingOphthalmology, 2008
- High-speed Optical Coherence Tomography of Corneal OpacitiesOphthalmology, 2007
- Corneal Pachymetry Mapping with High-speed Optical Coherence TomographyOphthalmology, 2006
- Human Corneal Thickness and Its Impact on Intraocular Pressure MeasuresSurvey of Ophthalmology, 2000
- Micrometer-Scale Resolution Imaging of the Anterior Eye In Vivo With Optical Coherence TomographyArchives of Ophthalmology (1950), 1994