Visible Reflectance Hyperspectral Imaging: Characterization of a Noninvasive, in Vivo System for Determining Tissue Perfusion
Authors:
- 5 April 2002
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 74 (9) , 2021-2028
Abstract
We characterize a visible reflectance hyperspectral imaging system for noninvasive, in vivo, quantitative analysis of human tissue in a clinical environment. The subject area is illuminated with a quartz−tungsten−halogen light source, and the reflected light is spectrally discriminated by a liquid crystal tunable filter (LCTF) and imaged onto a silicon charge-coupled device detector. The LCTF is continuously tunable within its useful visible spectral range (525−725 nm) with an average spectral full width at half-height bandwidth of 0.38 nm and an average transmittance of 10.0%. A standard resolution target placed 5.5 ft from the system results in a field of view with a 17-cm diameter and an optimal spatial resolution of 0.45 mm. The measured reflectance spectra are quantified in terms of apparent absorbance and formatted as a hyperspectral image cube. As a clinical example, we examine a model of vascular dysfunction involving both ischemia and reactive hyperemia during tissue reperfusion. In this model, spectral images, based upon oxyhemoglobin and deoxyhemoblobin signals in the 525−645-nm region, are deconvoluted using a multivariate least-squares regression analysis to visualize the spatial distribution of the percentages of oxyhemoglobin and deoxyhemoglobin in specific skin tissue areas.Keywords
This publication has 18 references indexed in Scilit:
- Assessment of tissue viability using near-infrared spectroscopyBritish Journal of Plastic Surgery, 1998
- Interactions Between Electrical Activity and Cortical Microcirculation Revealed by Imaging Spectroscopy: Implications for Functional Brain MappingScience, 1996
- In vivo SPECTROPHOTOMETRIC EVALUATION OF NEOPLASTIC AND NON‐NEOPLASTIC SKIN PIGMENTED LESIONS–I. REFLECTANCE MEASUREMENTSPhotochemistry and Photobiology, 1991
- An investigation of factors affecting the accuracy of in vivo measurements of skin pigments by reflectance spectrophotometryPhysics in Medicine & Biology, 1990
- Ferroelectric liquid-crystal tunable filterOptics Letters, 1989
- Noninvasive techniques to evaluate the vaso-occlusive manifestations of sickle cell diseaseJournal of Pediatric Hematology/Oncology, 1985
- Spectrophotometric monitoring of arterial oxygen saturation in the fingertipMedical & Biological Engineering & Computing, 1980
- A noninvasive tissue reflectance oximeterAnnals of Biomedical Engineering, 1980
- A light emitting diode skin reflectance oximeterMedical & Biological Engineering & Computing, 1972
- Solc Birefringent FilterJournal of the Optical Society of America, 1958