Three‐dimensional motion corrected sensitivity encoding reconstruction for multi‐shot multi‐slice MRI: Application to neonatal brain imaging
Open Access
- 19 June 2017
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 79 (3) , 1365-1376
Abstract
Purpose: To introduce a methodology for the reconstruction of multi‐shot, multi‐slice magnetic resonance imaging able to cope with both within‐plane and through‐plane rigid motion and to describe its application in structural brain imaging.Theory and Methods: The method alternates between motion estimation and reconstruction using a common objective function for both. Estimates of three‐dimensional motion states for each shot and slice are gradually refined by improving on the fit of current reconstructions to the partial k‐space information from multiple coils. Overlapped slices and super‐resolution allow recovery of through‐plane motion and outlier rejection discards artifacted shots. The method is applied to T2 and T1 brain scans acquired in different views.Results: The procedure has greatly diminished artifacts in a database of 1883 neonatal image volumes, as assessed by image quality metrics and visual inspection. Examples showing the ability to correct for motion and robustness against damaged shots are provided. Combination of motion corrected reconstructions for different views has shown further artifact suppression and resolution recovery.Conclusion: The proposed method addresses the problem of rigid motion in multi‐shot multi‐slice anatomical brain scans. Tests on a large collection of potentially corrupted datasets have shown a remarkable image quality improvement. Magn Reson Med 79:1365–1376, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.Keywords
Funding Information
- European Research Council (319456)
- Medical Research Council (MR/K006355/1)
This publication has 33 references indexed in Scilit:
- Revised motion estimation algorithm for PROPELLER MRIMagnetic Resonance in Medicine, 2013
- Prospective motion correction in brain imaging: A reviewMagnetic Resonance in Medicine, 2012
- Improved least squares MR image reconstruction using estimates of k‐Space data consistencyMagnetic Resonance in Medicine, 2011
- Hybrid prospective and retrospective head motion correction to mitigate cross‐calibration errorsMagnetic Resonance in Medicine, 2011
- POCS-enhanced correction of motion artifacts in parallel MRIMagnetic Resonance in Medicine, 2010
- Intersection Based Motion Correction of Multislice MRI for 3-D in Utero Fetal Brain Image FormationIEEE Transactions on Medical Imaging, 2009
- Array compression for MRI with large coil arraysMagnetic Resonance in Medicine, 2007
- Optimally Sparse Multidimensional Representation Using ShearletsSIAM Journal on Mathematical Analysis, 2007
- Detection and elimination of motion artifacts by regeneration of k‐spaceMagnetic Resonance in Medicine, 2002
- Advances in sensitivity encoding with arbitrary k‐space trajectoriesMagnetic Resonance in Medicine, 2001