Evaluation of the flying focal spot technology in a wide-angle digital breast tomosynthesis system
Open Access
- 4 December 2024
- journal article
- research article
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 12 (S1) , S13009-15
Abstract
Even though digital breast tomosynthesis (DBT) is a well-established imaging modality, efforts to optimize system accuracy and efficiency are still ongoing. Currently, different modes of gantry and/or detector movement exist. The two main acquisition modes for acquiring DBT projection data are a continuous gantry motion mode and a step-and-shoot mode. In the continuous mode, the x-ray tube moves continuously while x-rays are generated in short pulses at specific angles around the breast. This has the potential for faster acquisition times compared with the step-and-shoot operation but incurs source motion blurring along the direction of the source motion. Source motion blurring has been shown to reduce technical image quality, as quantified by a number of metrics.1 – 5 In a step-and-shoot mode, the x-ray tube stops at each angular location to acquire a projection image. This eliminates source motion blur provided that the tube stops without inducing any mechanical instability but may result in a longer scan acquisition time and therefore an increased chance for patient motion artifacts.6Keywords
This publication has 30 references indexed in Scilit:
- Measurements of system sharpness for two digital breast tomosynthesis systemsPhysics in Medicine & Biology, 2012
- Effect of image quality on calcification detection in digital mammographyMedical Physics, 2012
- Quantification of scattered radiation in projection mammography: Four practical methods comparedMedical Physics, 2012
- Further factors for the estimation of mean glandular dose using the United Kingdom, European and IAEA breast dosimetry protocolsPhysics in Medicine & Biology, 2009
- Experimental validation of a three‐dimensional linear system model for breast tomosynthesisMedical Physics, 2008
- Three‐dimensional linear system analysis for breast tomosynthesisMedical Physics, 2008
- A computer simulation platform for the optimization of a breast tomosynthesis systemMedical Physics, 2007
- Additional factors for the estimation of mean glandular breast dose using the UK mammography dosimetry protocolPhysics in Medicine & Biology, 2000
- A comparison of physical image quality indices and observer performance in the radiographic detection of nylon beadsPhysics in Medicine & Biology, 1984
- The Sensitivity Performance of the Human Eye on an Absolute Scale*Journal of the Optical Society of America, 1948