Fast clearing RGD‐based near‐infrared fluorescent probes for in vivo tumor diagnosis
Authors:
- 31 May 2012
- journal article
- Published by Wiley in Contrast Media & Molecular Imaging
- Vol. 7 (4) , 390-402
Abstract
A fast clearing hydrophilic near‐infrared (NIR) dye ICG‐Der‐02 was used to constitute tumor targeting contrast agents. Cell adhesion molecule integrin αvβ3 served as the target receptor because of its unique expression on almost all sprouting tumor vasculatures. The purpose of this study was to synthesize and compare the properties of integrin αvβ3‐targeted, fast clearing NIR probes both in vitro and in vivo for tumor diagnosis. ICG‐Der‐02 was covalently conjugated to three kinds of RGD peptide including linear, monoeric cyclic and dimeric RGD to form three RGD‐based NIR probes. The integrin receptor specificities of these probes were evaluated in vitro by confocal microscopy. The dynamic bio‐distribution and elimination ratse were in vivo real‐time monitored by a near‐infrared imaging system in normal mice. Further, the in vivo tumor targeting abilities of the RGD‐based NIR probes were compared in αvβ3‐positive MDA‐MB‐231, U87MG and αvβ3‐negtive MCF‐7 xenograft mice models. Three RGD‐based NIR probes were successfully synthesized with good optical properties. In vitro cellular experiments indicated that the probes have a clear binding affinity to αυβ3‐positive tumor cells, with a cyclic dimeric RGD probe owing the highest integrin affinity. Dynamic bio‐distributions of these probes showed a rapid clearing rate through the renal pathway. In vivo tumor targeting ability of the RGD‐based porbes was demonstrated on MDA‐MB‐231 and U87MG tumor models. As expected, the c(RGDyK)2‐ICG‐Der‐02 probe displayed the highest tumor‐to‐normal tissue contrast. The in vitro and in vivo block experiments confirmed the receptor binding specificity of the probes. The hydrophilic dye‐labeled NIR probes exhibited a fast clearing rate and deep tissue penetration capability. Further, the αυβ3 receptor affinity of the three RGD‐based NIR probes followed the order of dimer cyclic > monomer cyclic > linear. The results demonstrate potent fast clearing probes for in vivo early tumor diagnosis. Copyright © 2012 John Wiley & Sons, Ltd.Keywords
This publication has 37 references indexed in Scilit:
- Evaluation of 99mTc-Labeled Cyclic RGD Peptide with a PEG4 Linker for Thrombosis Imaging: Comparison with DMP444Bioconjugate Chemistry, 2011
- Advantages of RGD peptides for directing cell association with biomaterialsBiomaterials, 2011
- NIR dyes for bioimaging applicationsCurrent Opinion in Chemical Biology, 2010
- Peptide-Based Probes for Targeted Molecular ImagingBiochemistry, 2010
- The use of fluorescent dyes and probes in surgical oncologyEuropean Journal of Surgical Oncology, 2010
- Improving Tumor Uptake and Pharmacokinetics of 64Cu-Labeled Cyclic RGD Peptide Dimers with Gly3 and PEG4 LinkersBioconjugate Chemistry, 2009
- Improving Tumor Uptake and Excretion Kinetics of 99mTc-Labeled Cyclic Arginine-Glycine-Aspartic (RGD) Dimers with Triglycine LinkersJournal of Medicinal Chemistry, 2008
- Novel Near-Infrared Fluorescent Integrin-Targeted DFO AnalogueBioconjugate Chemistry, 2007
- Near-Infrared Fluorescence Imaging of Tumor Integrin αvβ3 Expression with Cy7-Labeled RGD MultimersMolecular Imaging and Biology, 2006
- Design, Synthesis, and Evaluation of Near Infrared Fluorescent Multimeric RGD Peptides for Targeting TumorsJournal of Medicinal Chemistry, 2006