The Effect of Study Design Biases on the Diagnostic Accuracy of Magnetic Resonance Imaging for Detecting Silicone Breast Implant Ruptures: A Meta-Analysis
- 1 March 2011
- journal article
- research article
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 127 (3) , 1029-1044
Abstract
Background: The U.S. Food and Drug Administration has recommended that all silicone breast implant recipients undergo serial screening to detect implant rupture with magnetic resonance imaging. The authors performed a systematic review and meta-analysis to examine the effect of study design biases on the estimation of magnetic resonance imaging diagnostic accuracy measures. Methods: Studies were identified using the MEDLINE, EMBASE, ISI Web of Science, and Cochrane library databases. Two reviewers independently screened potential studies for inclusion and extracted data. Study design biases were assessed using the Quality of Diagnostic Accuracy Studies tool and the Standards for Reporting of Diagnostic Accuracy Studies checklist. Meta-analyses estimated the influence of biases on diagnostic odds ratios. Results: Among 1175 identified articles, 21 met the inclusion criteria. Most studies using magnetic resonance imaging (10 of 16) and ultrasound (10 of 13) examined symptomatic subjects. Magnetic resonance imaging studies evaluating symptomatic subjects had 14-fold higher diagnostic accuracy estimates compared with studies using an asymptomatic sample (relative diagnostic odds ratio, 13.8; 95 percent confidence interval, 1.83 to 104.6) and 2-fold higher diagnostic accuracy estimates compared with studies using a screening sample (relative diagnostic odds ratio, 1.89; 95 percent confidence interval, 0.05 to 75.7). Conclusions: Many of the published studies using magnetic resonance imaging or ultrasound to detect silicone breast implant rupture are flawed with methodologic biases. These methodologic shortcomings may result in overestimated magnetic resonance imaging diagnostic accuracy measures and should be interpreted with caution when applying the data to a screening population.Keywords
This publication has 46 references indexed in Scilit:
- Statistical methods to correct for verification bias in diagnostic studies are inadequate when there are few false negatives: a simulation studyBMC Medical Research Methodology, 2008
- Comparative Study of Breast Implant Rupture Using Mammography, Sonography, and Magnetic Resonance Imaging: Correlation with Surgical FindingsThe Breast Journal, 2008
- The Safety of Silicone Gel-Filled Breast ImplantsAnnals of Plastic Surgery, 2007
- A Practical Guide to Meta-AnalysisThe Journal of Hand Surgery, 2006
- Decision-Analysis Methodology in the Work-up of Women with Suspected Silicone Breast Implant RupturePlastic and Reconstructive Surgery, 1998
- Sonographic signs of breast implant rupture.American Journal of Roentgenology, 1996
- MR imaging of silicone breast implants: Evaluation of prospective and retrospective interpretations and interobserver agreementJournal of Magnetic Resonance Imaging, 1996
- Diagnosis of Silicone Gel Breast Implant Rupture by UltrasonographyPlastic and Reconstructive Surgery, 1996
- MRI Findings in Subjects with Breast ImplantsPlastic and Reconstructive Surgery, 1995
- Comparison of Mammography, Sonography, and Magnetic Resonance Imaging in the Detection of Silicone-Gel Breast Implant RuptureAnnals of Plastic Surgery, 1994