Single Pulse and Pulse Train Modulation of Cutaneous Electrical Stimulation: A Comparison of Methods
Authors:
- Esther M. van der HeideEHEsther M. van der Heide
- Jan R. BuitenwegJBJan R. Buitenweg
- Enrico MaraniEMEnrico Marani
- Wim L. C. RuttenWRWim L. C. Rutten
- 1 February 2009
- journal article
- research article
- Published by Wolters Kluwer Health in Journal Of Clinical Neurophysiology
- Vol. 26 (1) , 54-60
Abstract
: Changing the amplitude of single rectangular pulse stimuli (SP) has the disadvantage of recruiting tactile and nociceptive fibers in a changing, unknown proportion. Keeping the amplitude constant, but applying a varying number of pulses in a train is another way of stimulus variation, keeping the proportion constant. So, pulse trains (PT) with a variable number of pulses but fixed amplitude might be more suitable to study nonperipheral aspects of processing of stimuli. In this study, we compared the effects of PT and SP stimulation on subjective Numeric Rating Scale scores of perceived stimulus strength and evoked potentials (EP). A total of 41 healthy subjects were electrically stimulated at the left forearm or left middle fingertip using SP and PT stimuli. Numeric Rating Scale scores and EPs were averaged from 105 randomized stimuli at 5 stimulus amplitudes or number of pulses for each subject. The relationships between stimulus amplitudes or number of pulses, EP components and Numeric Rating Scale scores differed depending on the stimulation method and stimulus location. Although the repeatedly reported Numeric Rating Scale-EP (N150-P200) correlation was reproduced for SP at the fingertip, no significant correlation was found for SP stimulation at the forearm. For PT this correlation was found for both stimulus locations. These findings demonstrate that SP and PT involve different ways of processing. The two methods result in different Numeric Rating Scale scores and EP components. Furthermore, PT stimulation is less dependent on stimulus location.Keywords
This publication has 46 references indexed in Scilit:
- Neuromagnetic SII responses do not fully reflect pain scaleNeuroImage, 2006
- Human brain mechanisms of pain perception and regulation in health and diseaseEuropean journal of pain, 2005
- Lasers and other thermal stimulators for activation of skin nociceptors in humansNeurophysiologie Clinique, 2003
- Spatial summation of pain processing in the human brain as assessed by cerebral event related potentialsNeuroscience Letters, 2002
- Pain measurement with evoked potentials: combination of subjective ratings, randomized intensities, and long interstimulus intervals produces a P300-like confoundPain, 2000
- Phasic pupil dilation response to noxious stimulation in normal volunteers: Relationship to brain evoked potentials and pain reportPsychophysiology, 1999
- Neurophysiological evaluation of painElectroencephalography and Clinical Neurophysiology, 1998
- Variability of laser-evoked potentials: attention, arousal and lateralized differencesElectroencephalography and Clinical Neurophysiology/Evoked Potentials Section, 1993
- Response plasticity of pain evoked reactions in manPhysiology & Behavior, 1982
- Brain evoked potentials are functional correlates of induced pain in manPain, 1979