Arterial spin labeling at ultra‐high field: All that glitters is not gold
- 19 February 2010
- journal article
- research article
- Published by Wiley in International Journal of Imaging Systems and Technology
- Vol. 20 (1) , 62-70
Abstract
In the past decade, MRI perfusion imaging has become increasingly important in the radiological clinic. Herein, arterial spin labeling (ASL) represents a truly noninvasive method for assessment of hemodynamic changes. Recently, whole body scanners that operate at a field strength of 7 Tesla or above have become available, carrying the promise of higher signal to noise ratio. In this article, we discuss the basic ASL methods that are available today and the problems that may be encountered when implementing ASL on a high field scanner. Particularly, B0 and B1 field inhomogeneities and fluctuations in precession frequency due to respiration were measured at the level of the brain feeding arteries. The effect of these disturbances on ASL is being discussed as are other issues such as specific absorption rate and relaxation rates. It can be concluded that implementation of ASL on MRI systems with high field strength is not trivial, although the feasibility of ASL measurements has been demonstrated at 7 Tesla. Further improvements can be expected, for example by the use of local labeling coils and improved shimming and preparation methods. © 2010 Wiley Periodicals, Inc. Int J Imaging Syst Technol, 20, 62–70, 2010Keywords
This publication has 55 references indexed in Scilit:
- fMRI at 1.5, 3 and 7 T: Characterising BOLD signal changesNeuroImage, 2009
- Mild Cognitive Impairment and Alzheimer Disease: Patterns of Altered Cerebral Blood Flow at MR ImagingRadiology, 2009
- Initial results of cardiac imaging at 7 teslaMagnetic Resonance in Medicine, 2008
- Whole‐body imaging at 7T: Preliminary resultsMagnetic Resonance in Medicine, 2008
- Continuous flow‐driven inversion for arterial spin labeling using pulsed radio frequency and gradient fieldsMagnetic Resonance in Medicine, 2008
- MRI-based anatomical model of the human head for specific absorption rate mappingMedical & Biological Engineering & Computing, 2008
- Assessment of the Contribution of the External Carotid Artery to Brain Perfusion in Patients With Internal Carotid Artery OcclusionStroke, 2008
- High-field fMRI unveils orientation columns in humansProceedings of the National Academy of Sciences, 2008
- High resolution measurement of cerebral blood flow using intravascular tracer bolus passages. Part I: Mathematical approach and statistical analysisMagnetic Resonance in Medicine, 1996
- Magnetic resonance imaging of flow dynamics in the circle of Willis.Stroke, 1990