Outcomes of Total Elbow Arthroplasty for Rheumatoid Arthritis: Comparative Study of Three Implants
- 1 November 2005
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 87 (11) , 2439-2448
Abstract
Background: As the English-language literature on prosthetic elbow arthroplasty contains only two comparative studies of implants in contemporary use, to our knowledge, comparisons of prosthetic performance is difficult. An improved knowledge of comparative outcomes would be valuable in guiding implant selection. Methods: We identified three groups of consecutive patients who had undergone prosthetic elbow arthroplasty with the Souter-Strathclyde, Kudo, or Coonrad-Morrey implant for the treatment of rheumatoid arthritis. There were thirty-three elbows in each group. All procedures were done by or under the supervision of one surgeon. Surviving patients in whom the elbow had not been revised were followed for a mean of sixty-one months after treatment with the Souter-Strathclyde implant, sixty-seven months after treatment with the Kudo implant, and sixty-eight months after treatment with the Coonrad-Morrey implant. Clinical function was assessed on the basis of pain relief and the range of flexion. Survivorship was assessed with use of a life-table method, with revision surgery and radiographic signs of loosening as the end points. Results: The groups were comparable in terms of age, sex, and mean duration of follow-up. All three implant procedures relieved pain. Sustained improvement in the range of flexion was comparable among the three groups, with no implant procedure dramatically changing the fixed flexion deformity and all three improving maximum flexion. Revision surgery was needed because of infection, dislocation, and aseptic loosening. Survival of the Coonrad-Morrey implant was better than that of the other two implants. The five-year survival rates, with revision and radiographic signs of loosening as the end points, were 85% and 81% for the Souter-Strathclyde implant, 93% and 82% for the Kudo implant, and 90% and 86% for the Coonrad-Morrey implant. While radiographic evidence of loosening of the Coonrad-Morrey implants was less common, we noted focal osteolysis adjacent to 16% of these ulnar components and half of these cases progressed to frank loosening. Conclusions: The clinical function of these implants was similar in terms of pain relief and range of motion. We believe that component linkage with the Coonrad-Morrey implant prevents dislocation without increasing the risk of loosening. Level of Evidence: Therapeutic Level III. See Instructions to Authors for a complete description of levels of evidence.Keywords
This publication has 9 references indexed in Scilit:
- Total elbow arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2005
- Total elbow arthroplasty with the Kudo prosthesisInternational Orthopaedics, 2003
- Total elbow replacement using the Kudo prosthesisThe Journal of Bone and Joint Surgery. British volume, 2003
- Randomised trials in surgery: problems and possible solutionsBMJ, 2002
- The Souter-Strathclyde elbow arthroplastyThe Journal of Bone and Joint Surgery. British volume, 2002
- Revisions for aseptic loosening in Souter-Strathclyde elbow arthroplastyActa Orthopaedica, 2002
- Functional outcome comparison of semiconstrained and unconstrained total elbow arthroplastiesJournal of Shoulder and Elbow Surgery, 2000
- Failure of Total Hip Arthroplasty With a Precoated ProsthesisClinical Orthopaedics and Related Research, 1998
- Cementless or hybrid total elbow arthroplasty with titanium-alloy implantsThe Journal of Arthroplasty, 1994